Traps, Interceptors, Separators & Vents Flashcards

Understand the function and installation of traps and interceptors, along with venting systems and configurations in plumbing installations.

1
Q

Fill in the blank:

The vertical distance from the fixture outlet to the trap weir shall not exceed ______ inches.

A

24 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Fill in the blank:

A combination plumbing fixture is permitted to be installed on one trap provided that one compartment is not more than ______ inches deeper than the other compartment.

A

6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Where is a slip joint connection of a trap not permitted?

A

trap offset

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Fill in the blank:

Each fixture trap shall have a trap seal not more than ______ inches deep.

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

True or False:

A trap shall be larger than the drainage pipe into which the trap discharges.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

True or False:

Acid resistant traps shall be embedded in concrete.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Which location does not require a grease interceptor or automatic grease removal device?

A

residential kitchen

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the grease retention capacity for an interceptor with a flow-through rate of 10 GPM?

A

20 pounds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Fill in the blank:

______ shall be provided for inspection and maintenance of automatic grease removal devices.

A

Ready access

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Fill in the blank:

A wire basket on the discharge side of a clothes washer shall prevent the passage of solids ______ inch(es) or larger from being discharged into the public sewer.

A

1/2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

True or False:

The plumbing vent system may be used for purposes other than venting of the plumbing when approved by the code official.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Fill in the blank:

Where a rooftop is used for restaurant dining, open vent pipes shall terminate not less than ______ feet above the roof.

A

7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Fill in the blank:

Any increase in size for vent terminations shall be created not less than ______ inside the thermal envelope.

A

12 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Fill in the blank:

A vent stack is required when there are more than ______ branch intervals in a building.

A

five

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Fill in the blank:

If a vent extends more than ______ feet in developed length, then the vent shall be increased by one nominal pipe size for the entire length.

A

40

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the vent pipe size for a drainage system serving a 4” stack carrying 300 DFU with a developed length of 75 feet?

17
Q

True or False:

The developed length may be measured from the farthest point of vent connection to the drainage system to the vent termination outside the building.

18
Q

Fill in the blank:

Relief vents shall be provided for stacks having ______ or more branch intervals

19
Q

What is the maximum distance for a trap arm for a 1 1/4” trap with 1/4” per foot grade?

20
Q

What is the maximum distance for a trap arm for a 3” trap with 1/8” per foot grade?

21
Q

True or False:

Common vented trap fixtures shall be located on the same floor level.

22
Q

True or False:

Fixtures being vented by a horizontal wet vent must be on the same floor level.

23
Q

True or False:

A waste stack vent system is permitted to have 45-degree offsets within the stack.

24
Q

What is the maximum number of fixtures that can be served by a circuit vent?

25
Q

True or False:

When a circuit vented drain connects to a stack receiving waste from above, a relief vent is required.

26
Q

Which of the following fixtures is permitted to be served by an island fixture vent?

a. water closet
b. urinal
c. sink
d. service sink

27
Q

What is the maximum distance for a horizontal branch serving fixtures other than toilets in a single stack vent system?

28
Q

What is the minimum pipe size for a fixture branching vertically from a horizontal branch in a single stack vent system?

29
Q

Fill in the blank:

In a single stack vent system, stacks greater than two branch intervals shall not receive discharge from horizontal branches on the lower ______ floors.

30
Q

True or False:

Air admittance valves shall be permitted to be installed in plenums.