Timed Exam 5 Flashcards

1
Q

In assemblies used for structural fire resistance and fireresistance-rated construction, smoke partitions are required to extend from the top
of the foundation or floor below to the underside of the floor or roof sheathing,
deck or slab above or to the underside of the ceiling above where the ceiling
membrane is constructed to limit the _________________ of smoke.

A. transfer
B. accumulation
C. intensity
D. buildup

A

A - transfer
710.4 Continuity.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The maximum distance of travel from any point within a mall
to an exit may not exceed ____________________.

A. 50 feet
B. 100 feet
C. 150 feet
D. 200 feet

A

D - 200 feet
402.8.5 Distance to exits.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A manual actuation fire-extinguishing device must be located
at or near a means of egress from the cooking area not less than ______ and not
more than _______ from the kitchen exhaust system. Exception ignored.

A. 5 feet, 10 feet
B. 10 feet, 15 feet
C. 10 feet, 20 feet
D. 15 feet, 25 feet

A

C - 10 feet, 20 feet
[F] 904.12.1 Manual system
operation.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

In buildings constructed in accordance with the provisions of
conventional light-frame construction what is the maximum laterally unsupported
height (in feet) of a 2x4 stud in a nonbearing wall.

A. 10 feet
B. 14 feet
C. 16 feet
D. 20 feet

A

B - 14 feet
TABLE 2308.5.1 SIZE, HEIGHT
AND SPACING OF WOOD STUDS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the fire resistance rating requirement for primary
structural frame including columns, girders, trusses in a type V-B structure?

A. 0 hours
B. 1hour
C. 2 hours
D. HT

A

A - 0 hours
TABLE 601 Fire-Resistance Rating
Requirements For Building
Elements (Hours)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The door component of a fire door assembly.

A. fire block
B. fire damper
C. fire door
D. fire stop

A

C - fire door
Chapter 2, Definitions.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the maximum allowable span for rafters of #1 Douglas
Fir-Larch 2X8s spaced 16 inches o.c. ground snow load = 30 psf, L/D = 180, dead
load = 10 psf? Ceiling is not attached to the rafters.

A. 10 feet 2 inches
B. 12 feet 4 inches
C. 14 feet 4 inches
D. 16 feet 2 inches

A

D - 16 feet 2 inches
Table 2308.7.2(3) Rafter Spans For
Common Lumber Species

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Glazing in guards and railings, including structural baluster
panels and nonstructural in-fill panels, ___________________ above a walking
surface is considered hazardous location.

A. within 36 inches
B. regardless of area or height
C. within 60 inches
D. within 42 inches

A

B - regardless of area or height
2406.4.4 Glazing in guards and
railings.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

A reinforced 8” masonry foundation wall is 8 feet high. The
lateral backfill soil load is 60 psf. The unbalance backfill height is 7 feet. What is
the required re-bar size and spacing?

A. #4 at 48”
B. #5 at 48”
C. #6 at 48”
D. #7 at 48”

A

D - #7 at 48”
TABLE 1807.1.6.3(2) 8-Inch
Masonry Foundation Walls With
Reinforcement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the minimum allowable thickness of concrete exterior
basement walls and foundation walls? Exceptions ignored.

A. 6 inches
B. 7 1/2 inches
C. 8 inches
D. 10 Inches
E. not be less than the thickness of the wall supported

A

E - not be less than the thickness of the wall supported
1807.1.6.1 Foundation wall
thickness

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Stairways within dwelling units and exterior stairways serving
a dwelling unit are required to have an illumination level on tread runs of not less
than _____ .

A. 1 foot-candle
B. 5 foot-candles
C. 10 foot-candles
D. 20 foot-candles

A

A - 1 foot-candle
1205.4 Stairway illumination.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the allowable area of a Group F-2 single story
building of Type IIIB Construction equipped throughout with an automatic sprinkler
system?.

A. 18,000 square feet
B. 18,000 square feet
C. 36,000 square feet
D. 72,000 square feet

A

D - 72,000 square feet
TABLE 506.2a, b ALLOWABLE
AREA FACTOR (At = NS, S1,
S13R, or SM, as applicable) IN
SQUARE FEET

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Fasteners used for the attachment of gypsum board to a
horizontal diaphragm ceiling must be spaced not more than _________ on center
(o.c.) at all supports, including perimeter blocking, and not more than ________
from the edges and ends of the gypsum board.

A. 4 inches, 1/2 inch
B. 7 inches, 3/8 inch
C. 9 inches, 3/8 inch
D. 10 inches, 1/2 inch

A

B - 7 inches, 3/8 inch
2508.6.4 Fasteners.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

In assemblies used for structural fire resistance and fireresistance-rated construction, fire walls, where combustible members frame into
hollow walls or walls of hollow units, hollow spaces must be solidly filled for the full
thickness of the wall and for a distance not less than 4 inches
__________________________ the structural members, with noncombustible
materials approved for fireblocking.

A. above
B. below
C. between
D. All of the above

A

D - All of the above
706.7 Combustible framing in fire
walls.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Gypsum board used in a horizontal diaphragm ceiling must be
installed _________________ to ceiling framing members. End joints of adjacent
courses of gypsum board may not occur on the same joist.

A. in line with
B. opposite
C. parallel
D. perpendicular

A

D - perpendicular
2508.6.2 Installation.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the minimum allowable thickness of exterior walls in a
masonry construction one-story building?

A. 6 inches
B. 8 inches
C. 10 inches
D. 12 inches

A

C - 10 inches
2109.2.4.4 Wall thickness.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

The thickness of concrete floor slabs supported directly on the
ground shall not be less than _____________. Exceptions ignored.

A. 2 inches
B. 3 inches
C. 31/2 inches
D. 4 inches

A

C - 31/2 inches
1907.1 Minimum Slab Provisions,
General

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What is the maximum allowable span for floor joist of #2
Southern Pine 2X12s spaced 12 inches o.c. in residential living areas, live load =
40 psf, L/D = 360, dead load = 10 psf.

A. 10 feet 3 inches
B. 13 feet 6 inches
C. 16 feet 2 inches
D. 19 feet 1 inch

A

D - 19 feet 1 inch
Table 2308.4.2.1(2) Floor Joist Spans For Common Lumber Species

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Aerosol product rooms and general-purpose warehouses
containing aerosol products must be provided with an approved _____________
fire alarm system where required by the International Fire Code.

A. manual
B. automatic
C. remote controlled
D. fume activated

A

A - manual
[F] 907.2.15 Aerosol storage uses.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

In assemblies used for structural fire resistance and fireresistance-rated construction, each portion of a building separated by one or more
fire walls that comply with the provisions of the fire wall section of the code is to be
considered ______________________, and the extent and location of such fire
walls shall provide a complete separation.

A. a separate room
B. a separate partition
C. a separate building
D. a separate fire zone

A

C - a separate building
706.1 General.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

______________________ occupancy includes, among
others, the use of a building or structure, or a portion thereof, for office,
professional or service-type transactions, including storage of records and
accounts.

A. Group A
B. Group B
C. Group E
D. Group U

A

B - Group B
304.1 Business Group B.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Direction signage indicating the location of the other means of
egress and which are accessible means of egress must be provided at which of
the following locations?

A. At exits serving a required accessible space but not providing an
approved accessible means of egress.
B. At elevator landings.
C. Within areas of refuge.
D. All of the above

A

D - All of the above
1009.10 Directional signage.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

In assemblies used for structural fire resistance and fireresistance-rated construction, the fire-resistance rating of exterior walls with a fire
separation distance of __________ than 10 feet shall be rated for exposure to fire
from the inside.

A. less
B. greater
C. 10 feet or less
D. 20 feet or less

A

B - greater
705.5 Fire-resistance ratings.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

In assemblies used for structural fire resistance and fireresistance-rated construction, fire walls are to be constructed of
__________________________________. Ignoring all exceptions.

A. sheetrock, concrete or steel.
B. concrete or steel materials
C. any approved non-combustible materials
D. wood, sheetrock, concrete or steel.

A

C - any approved noncombustible materials 706.3 Materials.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
In assemblies used for structural fire resistance and fireresistance-rated construction, each opening through a fire wall must be protected in accordance with the code and may not exceed _______ . The aggregate width of openings at any floor level shall not exceed _______ of the length of the wall. Exceptions ignored. A. 144 square feet, 20 percent B. 100 square feet, 15 percent C. 156 square feet, 25 percent D. 32 square feet, 10 percent
**C. 156 square feet, 25 percent** 706.8 Openings.
25
What is the minimum required thickness in inches for concrete floor slabs supported directly on the ground? Exceptions ignored. A. 3 inches B. 3-1/2 inches C. 4 inches D. 4-1/2 inches
**B - 3-1/2 inches** 1907.1 General.
26
In assemblies used for structural fire resistance and fireresistance-rated construction, draftstopping shall be installed to subdivide floor/ceiling assemblies. In other than Group R occupancies, draftstopping must be installed to subdivide combustible floor/ceiling assemblies so that horizontal floor areas do not exceed ________________. A. 500 square feet B. 750 square feet C. 1,000 square feet D. 2,000 square feet
**C - 1,000 square feet** 718.3 Draftstopping in floors.
27
The distance measured from the building face to the closest interior lot line, or to the centerline of a street, an alley or public way or to an imaginary line between two buildings on the property. A. fire separation distance B. building set back C. minimum wall distance D. allowable building line
**A - fire separation distance** Chapter 2, Definitions.
28
For the purpose of required natural lighting, any room is permitted to be considered as a portion of an adjoining room where _______ of the area of the common wall is open and unobstructed and provides an opening of not less than one-tenth of the floor area of the interior room or 25 square feet, whichever is greater. Exceptions ignored. A. one-half B. one-third C. one-quarter D. one-tenth
**A - one-half** 1204.2.1 Adjoining spaces.
29
A Hospital is an example of what type of Group Occupancy Classification? A. A-1 Group Occupancy B. B Group Occupancy C. I-1 Group Occupancy D. I-2 Group Occupancy
**D - I-2 Group** Occupancy 308.3 Group I-2.
30
What is the minimum normal weight concrete cover in inches that will provide a Fire-Resistance Rating of 1.5 hours for a W14 x 233 structural shape steel column? A. 1 inch B. 2 inches C. 2.5 inches D. 3 inches
**A - 1 inch** TABLE 722.5.1(7) Minimum Cover (Inch) For Steel Columns Encased In Normal-Weight Concrete
31
What is the maximum allowable span for floor joist of #1 Douglas Fir-Larch 2X10s spaced 16 inches o.c. in residential sleeping areas, live load = 30 psf, L/D = 360, dead load = 20 psf. A. 18 feet 5 inches B. 21 feet 4 inches C. 14 feet 5 inches D. 16 feet 5 inches
**D - 16 feet 5 inches** Table 2308.4.2.1(1) Floor Joist Spans For Common Lumber Species
32
Where _______________________ of any pane of glass are not firmly supported, or are subjected to unusual load conditions, detailed construction documents, detailed shop drawings and analysis or test data assuring safe performance for the specific installation are required to be prepared by a registered design professional. A. one or more sides B. layers C. sections D. rails
**A - one or more sides** 2403.2 Glass supports.
33
A fire-resistance-rated wall having protected openings, which restricts the spread of fire and extends continuously from the foundation to or through the roof, with sufficient structural stability under fire conditions to allow collapse of construction on either side without collapse of the wall. A. fire wall B. fire barrier C. fire stop D. fire block
**A - fire wall** Chapter 2, Definitions.
34
Exit passageway enclosures must have walls, floors and ceilings of not less than ____________ fire-resistance rating, and not less than that required for any connecting interior exit stairway or ramp. A. 1 hour B. 2 hour C. 3 hour D. 4 hour
**A - 1 hour** 1024.3 Construction
35
What is the maximum allowable span center to center for rafters or roof trusses in inches for 3/4 inch thick wood structural panel sheathing single floor grade applied to a roof? The panel span rating is 24 inches o.c. and the edges are supported between the framing members. A. 16 inches B. 20 inches C. 24 inches D. 32 inches E. 48 inches
**E - 48 inches** table 2304.8(3) allowable spans and loads for wood structural panel sheathing and single-floor grades continuous over two or more spans with strength axis perpendicular to supports
36
n assemblies used for structural fire resistance and fireresistance-rated construction, where protection of the vertical opening by approved shutters at every penetrated floor is permitted in accordance with this the code. The shutters must be of noncombustible construction and have a fireresistance rating of not less than ____________. A. .5 hours B. 1 hour C. 1.5 hours D. 2 hours
**C - 1.5 hours** 712.1.3.2 Automatic shutters
37
In reference to the LIB bracing method, the LIB stands for what? A. Linear-Integral-Bracing B. Linear-In Line-Bracing C. Lateral-Internal-Bracing D. Let-in-Bracing
**D - Let-in-Bracing** Table 2308.6.3(1) Bracing Methods
37
_________________ construction is that type of construction in which the exterior walls are of noncombustible materials and the interior building elements are of any material permitted by the code. A. Type I B. Type II C. Type III D. Type IV
**C - Type III** 602.3 Type III.
38
In buildings constructed in seismic design categories D and E accordance with the provisions of conventional light-frame construction, exterior exit balconies, stairs and similar exit facilities are to be positively anchored to the primary structure at not over ____________________ or shall be designed for lateral forces. Such attachment may not be accomplished by use of toenails or nails subject to withdrawal. A. 2 feet o.c. B. 4 feet o.c. C. 6 feet o.c. D. 8 feet o.c.
**D - 8 feet o.c.** 2308.4.10 Anchorage of exterior means of egress components in Seismic Design Categories D and E.
39
Group A-3 occupancies where the fire area has an _____________________ will require an automatic sprinkler system. A. occupant load of 100 or more B. occupant load of 200 or more C. occupant load of 300 or more D. occupant load of 400 or more
**C - occupant load of 300 or more** [F] 903.2.1.3 Group A-3. 2
40
In assemblies used for structural fire resistance and fireresistance-rated construction, where the fire wall intersects the exterior walls, the fire-resistance rating for the exterior walls on both sides of the fire wall shall have a 1-hour fire-resistance rating with 3/4-hour opening protection where opening protection is required. The fire-resistance rating of the exterior wall shall extend a minimum of _____________ on each side of the intersection of the fire wall to exterior wall. A. 2 feet B. 4 feet C. 6 feet D. 8 feet
**B - 4 feet** 706.5.1 Exterior walls. 1.
41
The occupant load of a nonsprinklered space is 350 occupants. What is the minimum required combined clear width of the egress doors serving that space? A. 60 inches B. 70 inches C. 80 inches D. 100 inches
**B - 70 inches** 1005.3.2 Other egress components. Answer: 350 occupants x 0.2 inches per occupant = 70 inches
42
Mercantile Group M. Mercantile Group M occupancy includes, among others, buildings and structures or a portion thereof, for the display and sale of merchandise, and involves stocks of goods, wares or merchandise incidental to such purposes and _________________________. A. is accessible to the public B. private storage areas C. is for employee use only D. no one admitted
**A - is accessible to the public** 309.1 Mercantile Group M.
43
For open roof valleys (valley lining exposed) lined with metal, the valley lining must be not less than ______________ wide and of any of the corrosion-resistant metals in Table 1507.2.9.2. A. 16 inches B. 20 inches C. 24 inches D. 28 inches
**C - 24 inches** 1507.2.8.2 Valleys. 1.
44
Rooms or spaces having a floor area larger than ________ , containing a refrigerant evaporator and maintained at a temperature below 68°F, shall have access to not less than two exits or exit access doors. A. 500 square feet B. 1000 square feet C. 1500 square feet D. 2000 square feet
**B - 1000 square feet** 1006.2.2.3 Refrigerated rooms or spaces.
45
An automatic sprinkler system shall be provided for all enclosed Group A-5 accessory use areas in excess of___________________________. A. 500 square feet B. 750 square feet C. 1,000 square feet D. 2,000 square feet
**C - 1,000 square feet** [F] 903.2.1.5 Group A-5.
46
In Type I and II construction, The use of combustible piping materials is permitted when installed in accordance with the limitations of the _____________________________________________________________. A. International Mechanical Code and the International Plumbing Code B. UBC C. NFPA D. Plumbing Pipe Association of America
**A - International Mechanical Code and the International Plumbing Code** 603.1.2 Piping.
47
A listed device that senses visible or invisible particles of combustion. A. smoke detector B. smoke alarm C. nuisance alarm D. thermal detector
**A - smoke detector** Chapter 2, Definitions
48
In a covered mall building, there must be a minimum of ________ clear exit width to a height of 8 feet between any projection of a tenant space bordering the mall and the nearest kiosk, vending machine, bench, display opening, food court or other obstruction to means of egress travel. A. 8 feet B. 10 feet C. 12 feet D. 14 feet
**B - 10 feet** 402.8.1.1 Minimum width.
49
Stairways that are part of the means of egress for the exterior area for assisted rescue must provide a minimum clear width of ___________________ between handrails A. 36 inches B. 40 inches C. 44 inches D. 48 inches
**D - 48 inches** 1009.7.4 Stairways
50
The building official is authorized to issue a permit for the construction of foundations or any other part of a building or structure before the construction documents for the whole building or structure have been submitted, provided that adequate information and detailed statements have been filed complying with pertinent requirements of the code. The IBC calls this kind of approval _______________________. A. Pre-approval B. Conditional approval C. Temporary approval D. Phased approval.
**D - Phased approval.** [A]107.3.3 Phased approval.
51
A wall designed to resist lateral forces parallel to the plane of a wall. A. Braced wall B. Cripple wall C. Vertical wall D. Shearwall
**D - Shearwall** Chapter 2, Definitions.
52
What is the minimum allowable horizontal area of a window well use for emergency escape? A. 6 square feet B. 8 square feet C. 9 square feet D. 10 square feet
**C - 9 square feet** 1030.4.1 Minimum size.
53
What is the minimum thickness face-to-face required for a wall constructed from wood studs interior partition with gypsum wallboard each side 2X4 wood studs 24 inch on center with 5/8 inch type x gypsum wallboard applied vertically or horizontally nailed with 6d cooler or wallboard nails at 7 inch on center with end joints on nailing members, stagger joints each side, to have a fire resistance rating of 1 hour? A. 3.5 inches B. 4.75 inches C. 5.75 inches D. 6.75 inches
**B - 4.75 inches** TABLE 721.1(2) Rated FireResistance Periods For Various Walls And Partitions, Item 14-1.3
54
Cement used to produce concrete shall comply with_______________________. A. CPI, Section 801.90 B. ACI 318 C. NACA 318.90 D. CIA, Section 405
**B - ACI 318** 1903.1 General
55
Permit fees are not refunded unless: A. The applicant changes his mind on starting the project. B. The permit is rejected. C. The building official is authorized to establish a refund policy. D. The applicant has just cause for a refund.
**C - The building official is authorized to establish a refund policy.** [A]109.6 Refunds.
56
As applied to fire protection devices, a device or system providing an emergency function without the necessity for human intervention and activated as a result of a predetermined temperature rise, rate of temperature rise or combustion products. A. sensor B. automatic C. remote controlled D. manual
**B - automatic** Chapter 2, Definitions.
57
Where masonry chimneys are constructed as part of masonry or concrete walls, combustible materials shall not be in contact with the masonry or concrete wall less than _________ from the inside surface of the nearest flue lining. A. 2 inches B. 6 inches C. 12 inches D. 18 inches
**C - 12 inches** 2113.19 Chimney clearances. Exception. 2
58
Group A-3 occupancies where the fire area exceeds_____________ will require an automatic sprinkler system. A. 10000 square feet B. 12000 square feet C. 14000 square feet D. 16000 square feet
**B - 12000 square feet** [F]903.2.1.3 Group A-3., 1.
59
Which of the following is not required to be included in the construction documents for structural concrete construction? A. The magnitude and location of prestressing forces. B. The specified strength or grade of reinforcement. C. Name and location of the concrete mixing plant. D. Stressing sequence for post tensioning tendons.
**C - Name and location of the concrete mixing plant.** 1901.5 Construction documents.
60
In buildings constructed in accordance with the provisions of conventional light-frame construction in seismic design category A the buildings are limited to a maximum of ______ above grade. A. 1 stories B. 2 stories C. 3 stories D. 4 stories
**C - 3 stories** Table 2308.2.1
61
Parapet walls shall be properly coped with noncombustible, weatherproof materials of a width _______________. A. of 8 inches minimum B. no less than the thickness of the parapet wall C. of 12 inches minimum D. none of these
**B - no less than the thickness of the parapet wall** 1503.3 Coping.
62
An automatic sprinkler system must be provided for Group A5 occupancies in accessory use areas in excess of _______________. A. 1000 square feet B. 2000 square feet C. 3000 square feet D. 4000 square feet
**A - 1000 square feet** [F] 903.2.1.5 Group A-5.
63
An exit component that is separated from other interior spaces of a building or structure by fire-resistance-rated construction and opening protectives, and provides for a protected path of egress travel in a horizontal direction to the exit discharge or the public way. A. exit passageway B. exit enclosure C. exit access D. exit discharge
**A - exit passageway** CHAPTER 2 DEFINITIONS
64
What is the fire resistance rating requirement for floor construction and secondary members in a type III-B structure? A. 0 hours B. 1 hour C. 2 hours D. 3 hours
**A - 0 hours** TABLE 601 Fire-Resistance Rating Requirements For Building Elements (Hours)
65
This Type of Construction is that in which the exterior walls are of noncombustible materials and the interior building elements are of solid wood, laminated wood, heavy timber (HT) or structural composite lumber (SCL) without concealed spaces. A. Type III B. Type IV C. Type V D. Type VI
**B - Type IV** 602.4 Type IV.
66
Sheathing nails or other approved sheathing connectors shall be driven so that their head or crown __________ the surface of the sheathing. A. penetrates B. is flush with C. is counter sunk into D. splits
**B - is flush with** 2304.10.2 Sheathing fasteners.
67
What is the maximum number of occupants allowed in a bowling center in bowling areas? A. 7 net, persons for each lane B. 5 persons for each lane including 15 feet of runway C. no limit D. 15 gross, persons for each lane
**B - 5 persons for each lane including 15 feet of runway** Table 1004.5 Maximum Floor Area Allowances Per Occupant
68
Any tower, spire, dome or cupola that exceeds 60 feet in height above the highest point at which it comes in contact with the roof, or that exceeds 200 square feet in area at any horizontal section, or which is intended to be used for any purpose other than a belfry or architectural embellishment, must be entirely constructed of and supported by noncombustible materials and must be separated from the building below by construction having a fire-resistance rating of not less than ________ hours. rating. A. 1-1/2 hours B. 2 hours C. 2-1/2 hours D. 1 hours
**A - 1-1/2 hours** 1510.5.1 Noncombustible construction required.
69
For detached structures accessory to occupancies in Group R-3, such as garages, utility buildings or other unheated facilities a vapor barrier _______ mil thick is required. A. 2 B. 3 C. 6 D. no vapor barrier is required
**D - no vapor barrier is required** 1907.1 General. Exceptions 1.
70
In assemblies used for structural fire resistance and fireresistance-rated construction, approved fire door and fire shutter assemblies are to be constructed of ______________ or assembly of component materials that conforms to the test requirements of the fire resistance and fire-resistance-rated construction outline in the code. A. any material B. steel C. treated wood D. aluminum
**A - any material** 716.5 Fire door and shutter assemblies
71
Class C roof assemblies are those that are effective against _______________. A. light fire-test exposure B. moderate fire-test exposure C. extreme fire-test exposure D. no fire-test exposure
**A - light fire-test exposure** 1505.4 Class C roof assemblies.
72
With respect to masonry fireplaces, cleanout openings, located within foundation walls below fireboxes, when provided, must be equipped with ________________________ and frames constructed to remain tightly closed, except when in use. A. ferrous metal or masonry doors B. glass doors C. aluminum metal or masonry doors D. any of these
**A - ferrous metal or masonry doors** 2111.3.1 Ash dump cleanout.
73
The triangular openings at the open sides of a stair formed by the riser, tread and bottom rail at the open side of a stairway must be of a maximum size such that a sphere of ______________ in diameter cannot pass through the opening. A. 4 inches B. 6 inches C. 8 inches D. 10 inches
**B - 6 inches** 1015.4 Opening limitations. Exceptions 2
74
A Single Family Home is and example of what occupancy group? A. R-1 occupancy group B. R-2 occupancy group C. R-3 occupancy group D. R-4 occupancy group
**C - R-3 occupancy group** 310.1 Residential Group R.
75
In assembly seating the aisle width must provide sufficient egress capacity for the number of persons accommodated by the ____________ area served by the aisle. A. building B. seating C. open D. catchment
**D - catchment** 1029.9.2 Aisle catchment area.
76
Glazing in fixed and sliding panels of sliding door assemblies and panels in sliding and bifold closet door assemblies’ _________________. A. is not allowed B. must be double glazed C. is considered a hazardous location installation D. must be unbreakable
**C - is considered a hazardous location installation** 2406.4.1 Glazing in doors.
77
Inlets to masonry chimneys must enter from the side and have a ________ of fireclay, rigid refractory material or metal that will prevent the connector from pulling out of the inlet or from extending beyond the wall of the liner. A. funnel B. fire door C. vent D. thimble
**D - thimble** 2113.17 Inlet.
78
The use of the provisions for conventional light-frame construction in this section are not to be permitted for buildings in Seismic Design Categories B, C, D, E or F. A. A B. B C. C D. D, E and F E. All the above except A
**E - All the above except A** 2308.2.6 Risk category limitation.
79
Listed materials used as chimney flue linings must be installed in accordance with the terms of their listings and the_______________________. A. UL B. contractor's experience C. UBC D. manufacturer’s instructions
**D - manufacturer’s instructions** 2113.13.1 Listed materials.
80
An intermediate level or levels between the floor and ceiling of any story and in accordance with Section 505. A. gallery B. stage C. mezzanine D. platform
**C - mezzanine** Chapter 2, Definitions.
81
What is the required separation of occupancies (hours) between a Group A and Group M? The Buildings are equipped throughout with an automatic sprinkler system. A. 1hour B. 2 hours C. 3 hours D. NP (Not Permitted)
**A - 1hour** TABLE 508.4 Required Separation Of Occupancies (Hours)
82
The minimum width of each means of egress door opening must be sufficient for the occupant load thereof and provide a clear width of not less than _______ . Exceptions ignored. A. 24 inches B. 32 inches C. 36 inches D. 42 inches
**B - 32 inches** 1010.1.1 Size of doors.
83
The building official has the authority to require tests as evidence of compliance to be made at no expense to the jurisdiction. A. The test methods must be designed by an architect. B. The test methods must be UL Listed. C. The test methods must be as specified in the code or by other recognized test standards. D. The test methods must be newly proven.
**C - The test methods must be as specified in the code or by other recognized test standards.** [A] 104.11.2 Tests.
84
What is the minimum thickness face-to-face required for a wall constructed from solid gypsum plaster, studless with 1/2 inch full-length plain gypsum lath and perlite or vermiculite gypsum plaster each side, to have a fire resistance rating of 2 hours? A. 2 inches B. 2.5 inches C. 3 inches D. 3.5 inches
**B - 2.5 inches** TABLE 721.1(2) Rated FireResistance Periods For Various Walls And Partitions, Item 6-2.2
85
What is the fire resistance rating requirement for the primary structural frame Including columns, girders, trusses excluding roof support members in a Type I-B structure? A. 0 hours B. 1 hour C. 2 hours D. 3 hours
**C - 2 hours** TABLE 601 Fire-Resistance Rating Requirements For Building Elements (Hours)
86
The unobstructed width of pedestrian walkways shall not be less than _____. The total width shall not exceed _____. A. 32 inches, 24 feet B. 36 inches, 30 feet C. 42 inches, 25 feet D. 44 inches, 30 feet
**B - 36 inches, 30 feet** 3104.8 Width.
87
What is the maximum allowable travel distance between fire extinguishers for Class A fire hazards in a extra high hazard occupancy setting? A. 35 feet B. 50 feet C. 75 feet D. 100 feet
**C - 75 feet** [F]TABLE 906.3(1) Fire Extinguishers For Class A Fire Hazards
88
Guards must be provided where appliances, equipment, fans, roof hatch openings or other components that require service are located within ________ of a roof edge or open side of a walking surface and such edge or open side is located more than _______ above the floor, roof or grade below. A. 10 feet, 48 inches B. 8 feet, 30 inches C. 8, 24 inches D. 10 feet, 30 inches
**D - 10 feet, 30 inches** 1015.6 Mechanical equipment, systems and devices.