TIME INTERVALS Flashcards
NDE - Minimum time an examiner should be in a darkened area prior to using a black light for MT & PT exams
5 minutes
NDE - Final interpretation of a PT exam after application of developer (time range)
10-60 minutes
Testing – Typical minimum duration for a pressure test
30 minutes
NDE - Minimum time to wait to check for delayed cracking after repairs to SS cladding
24 hours
NDE - Max Calibrating Interval - RT densitometer
3 months
Welding – Max Time a Welder or Welding Operator maintains qualifications for a process without using that process
6 months
NDE - Maximum Interval for a visual examiner’s eye exam
1 year
Insp - Maximum Interval for Internal Inspection if Remaining Life is less than 4 Years
Lesser 2 yr or Full Life
Insp - Maximum Interval - External Inspection
Lesser 5 yr or Internal
Insp - Maximum Interval for Relief devices in fouling or corrosive service
5 year
Insp - Maximum Interval for Internal or On-Stream Inspection
Lesser 10 yr or ½ Life
Insp - Maximum Interval for Relief devices in non-fouling or non-corrosive service
10 years
RBI - Maximum Interval for the RBI Reassessment
10 years
Insp - Minimum Remaining Life required when performing an On-stream inspection in lieu of an Internal Inspection
> 10 years
NDE - Max Calibrating Interval – For all MT Magnetic Yokes
Before use