Thermostat Wiring Flashcards

1
Q

The thermostat acts as a __________ between the R terminal and the other terminals.

A

Switch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

During heating mode, the furnace thermostat connects the R terminal to…

A

The *W terminal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

During fan mode, the thermostat connects the R terminal to…

A

*G Terminal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The color code usually used for 24v thermostat wiring is Red for R, Green for G, Yellow for Y, and ________ for C.

A

Blue

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

During AC mode, the furnace and AC thermostat connects the R terminal to…

A

The *Y and *G terminal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What happens if you accidentally connect the C wire, which is typically blue, to the B terminal in the thermostat?

A

The 24v fuse could blow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

During air conditioning mode, when the heat pump thermostat is set to a lower temperature than it is in the building, the R terminal connects to…

A

The *Y *G and *O Terminals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

During heating mode on a heat pump thermostat, when the thermostat is set 1 degree higher than the current temperature in the building, the thermostat connects the R terminal to the…

A

The *Y *G and *B terminals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

During heating mode on a heat pump thermostat, when the thermostat is set 3 degrees higher than the current temperature in the building, the thermostat connects the R terminal to the…

A

The *Y *Aux *G and *B terminals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

After you turn OFF the power to a 24v thermostat and turn it back ON, there is usually a ___ minute on-delay before it can send a signal to turn on the refrigerant compressor.

A

Five

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

If the battery operated thermostat starts working intermittently, first replace the…

A

Batteries

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

On a furnace and ac unit, you can verify that the thermostat is calling for air conditioning to turn on by measuring for 24v at the furnace control board. Put the multimeter probes on the…

A

The *Y and *C terminals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

You can verify if the thermostat is calling for the indoor fan to turn on by measuring for 24v at the HVAC unit’s control board. Put the multimeter probes on the…

A

*G and *C Terminals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

On a furnace, you can tell that the thermostat is calling for the heat to turn on by measuring for 24v at the furnace control board. Put the multimeter probes on the…

A

*W and *C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If the air handler’s indoor fan continues to run even when the 24v thermostat face is removed, test for 24v at the control board first between the…

A

*G and *C terminals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If a furnace’s indoor fan continues to run even with the 24v thermostat face removed, the problem could be the thermostat wires touching, fan relay contacts stuck closed, ECM Blower module, or…

A

Safety limit open

17
Q

If the 3 amp 24v fuse blows when the HVAC unit is turned on, even when the thermostat face has been removed, this means that the _____________ are likely touching.

A

R and C wires

18
Q

On an air conditioning only unit, if the 5 amp 24v fuse only blows when the thermostat calls for air conditioning to turn on, this means that the _____________ is likely touching the C wire.

A

Y or G wire

19
Q

On a Heat pump, if the 5 amp 24v fuse only blows when the thermostat calls for air conditioning to turn on, this means that the _____________ is likely touching the C wire.

A

Y O or G wire

20
Q

On a Heat pump, if the 5 amp 24v fuse only blows when the thermostat calls for heat to turn on, this means that the _____________ is likely touching the C wire.

A

Y B or G wire

21
Q

If all your wires are correct at the thermostat where else do you check?

A

Check at your control board the wires might not be matched up correctly