Hvac Revamped Flashcards

1
Q

What is the purpose of a receiver tank?

A

It stores sub cooled liquid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The sight glass is upstream of (right before) the…..,

A

Metering device

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The king valve is on the outlet of the…

A

Receiver

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which of these refrigerants is NOT used in refrigerators and freezers?
R-22
R-410A
R-404A
R-134A

A

R-410A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

On a automatic pump-down refrigeration system, which component opens the electrical circuit to the compressor to turn off?

A

The Low pressure switch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Which can cause the evaporator to freeze up on a reach in commercial refrigerator?

A

Blocking the airflow with too much product

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

If a system with a new filter drier has been running for 15 minutes, seeing bubbles in the liquid line sight glass means there is…..,.,,

A

No subcooling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

If the defrost cycle does not intimate on a freezer,the (blank) will continue to attract humidity to it and completely freeze over

A

Evaporator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

If a fuse blows what does that mean?

A

fuse blows anytime one of your energized circuits make contact with common or ground without first going through a load first

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What are three ways to check for a blown fuse?

A

1.loose wire nut connection
2. One of the wires loose from the terminal
3.one of the wires cut or damaged

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

With your volt meter how do you test for a blown fuse?

A

you would want to check continuity or you can check with ohms. If you have a OL reading it’s bad but if you get some type of resistance your fine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

If you have a OL reading while checking for ohms on a fuse what does that mean?

A

You should get some type of reading. If you get a OL reading, you have a bad fuse. Not passing electrical current

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Say your indoor blower motor not turning on. And you check from *G to *C and it’s getting 24v where would you check next?

A

Then with your probes you would want to check from your neutral wire to your fan speed wire on the circuit board. If you get nothing bad board

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

In defrost mode on a heat pump it’s basically running in normal ac mode at the condenser besides what?

A

The condensing fan is shut off not rejecting heat causing the outside coil to heat up faster

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

During defrost mode what is the .W terminal at the condenser doing?

A

Because you don’t want your heat to drop while it’s defrosting the outside coil it’s going to power 24v back at the control board and turn on your furnace or electrical heat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What two things trigger the heat pump from out of defrost mode?

A

Until a time commitment is met at 10min (or whatever it’s set too) or temperature sensor is satisfied

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What three reasons will cause the evaporator coil to freeze?

A
  1. Low indoor airflow
    2.low refrigerant charge
    3.liquid line restriction
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Sometimes technicians will try to raise the low side temperatures by charging the unit up instead of fixing the issue. How would you indicate this?

A

Very clear indication of this is very high subcooling anywhere from 21 and above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What does the compressor and the condenser fan motor have in common?

A

The COMMON START AND RUN windings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Where does the START wire go for you condensing fan and your compressor

A

On the compressor (blue) wire goes to the HERM on the capacitor and for the condensing fan it would be 1or 2 brown wires that goes to FAN on cap or it will have its own capacitor.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Where does the RUN wires go for your compressor and outdoor fan?

A

They both go to T2 on the contactor usually yellow.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Where would your COMMON wires go to your compressor and outdoor fan?

A

They would usually go to your T1 terminals on the contactor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

When you see 18 in the model number what’s the tonnage of the unit?

A

1.5 tons

24
Q

When you see 24 in the model number what is the size of the unit?

A

2 tons

25
Q

When you see 30 in the model number what’s the tonnage of the unit?

A

2.5 tons

26
Q

When you see a 36 in the model number what’s the tonnage?

A

3 tons

27
Q

When you see a 42 in the model number what’s the tonnage of the unit?

A

3.5 tons

28
Q

When you see a 48 in the model number what’s the tonnage of the unit?

A

4 ton

29
Q

When you see a 60 in the model number what’s the tonnage of the unit?

A

5 tons

30
Q

How would you test a defrost thermostat sensor?

A

DFT suppose to be normally open. So you would ohm/continuity it out to see if it’s closed or not. And a k temp probe

31
Q

How would you test a contactor?

A

You can unplug the 24v and ohm it out which would read around 14ohms. Or check to see if it’s passing power

32
Q

If the cool on or heat on is blinking what does that mean?

A

It’s in a 5 minute delay

33
Q

On a straight cool system and not a heat pump is there a delay?

A

No

34
Q

If a air handler does not have a board what does that mean?

A

That mean it has a Ecm motor for the indoor unit

35
Q

How can you test a thermostat?

A

If it’s not operating correctly jump out the wires. If it starts working when you jump it out at the thermostat but it doesn’t work when you operate it it’s your thermostat

36
Q

How does a float switch usually sit? Open or closed?

A

Closed

37
Q

Which circuit do you break to add in a float switch?

A

Primarily you want to break the R. But in other applications you can use Y. That’s the only two that produces condensation since it builds during cool

38
Q

How do you wire in a float switch?

A

One wire you want to wirenut to your 24v source for the transformer and the other you would want to connect to the R on your thermostat wire

39
Q

If your compressor stops working when you call for cool but your indoor fan works fine what could be the issue?

A

1.)They have a float/safety switch wired into the Y circuit in the indoor unit
2.)pressure switches at condenser
3.)defrost board
4.) bad contactor
5. Bad compressor

40
Q

On a condensation line what needs to be added and why?

A

A pe trap is needed for the line so that the water is able to drain when the ac is running by creating a vaccum

41
Q

On a heat pump when is the * Y energized, in cooling or heat mode?

A

Both

42
Q

If their is high humidity in the house do you set the fan speed lower or higher?

A

You set it lower

43
Q

On a heat pump system if you have a txv outside what should the superheat be around?

A

8-14 degrees

44
Q

When you look at the subcooling rating at the outside condenser it can be plus or minus by what?

A

Three

45
Q

If you have a 32 or below sat temp on the vapor line and the subcooling and superheat is within the plus or minus 3 what’s happening?

A

Low airflow issue, dirty filter/fan or low fan speed

46
Q

On a system if you have very high superheat and average subcooling with the sat temp of the vapor line below 32 what’s happening?

A

A liquid line restriction, bad txv or clogged filter dryer

47
Q

How would you troubleshoot shoot a Ecm motor?

A

Check for line and low voltage. So first stick the probes in on the *L and *N to look for line voltage. Then for 24v stick one probe at the common terminal and the other for the fan speed

48
Q

What are three ways a TXV fails?

A

1.the bulb lost its charge
2.it’s clogged
3.stuck in the closed position

49
Q

When working on a ECM motor if the furnace/ Air handler is on that means the motor is not receiving any voltage. True or False?

A

False if the furnace/ Air handler is on then it’s receiving voltage at the *L and *N wires on the high voltage side always

50
Q

The Ecm motor does not need 24v to turn on. True or False?

A

False. A Ecm motor should not turn on unless it gets a signal from the 24v. If it running without that signal you could have a bad motor

51
Q

True or False there should be continuity across all windings on a fan motor

A

True if their is no continuity between two windings the motor needs to be replaced and one of your wires is open

52
Q

Can a thermostat blow a fuse?

A

Yes

53
Q

If you have a jumper from *R to *Y and the fuse pops what could be wrong?

A
  1. It could be the wires itself going outside
  2. It could be the contactor
54
Q

Say your fuse pops every time you have power to *R and *Y how can you tell it’s the wires or contactor?

A

Well first undo the wire nuts that go to *y and *c that connects the indoor thermostat wire to the outdoor unit. And your jumpers and then add power. If it pops it’s your thermostat wire if not it’s the contactor

55
Q

When you ohm out your contactor coil how many ohms should you read?

A

Between 10-20 ohms. If you get anything below 8 it may start to trip the breaker or blow fuse

56
Q

If you don’t have 24v. What is one thing that is over looked?

A

Blown fuse