Test Review Flashcards

1
Q

Movement of fluid from one location to another?

A

Velocity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Fluid moving with a variable velocity accelerates and decelerates?

A

Pulsitile and Phasic flow?? (idk which she’s looking for)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Movement of fluid from one location to another that accelerates and decelerates w/ respiration?

A

Phasic Flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Flow pattern seen with normal physiological states?

A

Laminar Flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Chaotic flow in many directions and speeds?

A

Turbulent Flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Frictional loss, blood slide along vessel wall is considered what?

A

Heat?

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Reynolds number, turbulent flow?

A

> 2,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What the effects of stenosis are?

A

change in flow direction↑ velocity as vessels narrowsturbulence downstream from the stenosispressure gradient across the stenosisloss of pulsatility

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Next 5 questions are about hydrostatic pressure?These are all in supine

A

Ankle 140mmHg heart 0mmHg 140 mmHg (140 + 0) Knee ‘‘mid Chest ‘‘Top of head’’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Doppler shift provide info about what?

A

Velocity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Positive and negative Doppler shift?Positive

A

toward transducerreflected higher than transmittedarterial

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Positive and negative Doppler shift?Negative

A

away from transducerreflected lower than transmittedvenous

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Typical range of Doppler shift found in imaging examinations?

A

Audible20Hz - 20kHz

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

If the sample volume is deep, the PRF and Nyquist limit is what?

A

low, creates aliasing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Phenomenon high velocity is negative?

A

Aliasing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Five ways to eliminate aliasing?

A
  1. adjust scale2. shallower3. ↓ frequency4. Baseline5. Continuous Wave
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Large and small sample volumes, which will fill in on Doppler?

A

Large, spectral broading

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

X and Y axis on Doppler Spectrum?X

A

Time

19
Q

X and Y axis on Doppler Spectrum?Y

A

Shift or Velocity

20
Q

Doppler shift inversely related to?

A

Propagation Speed

21
Q

What is the basic Doppler system that simple identifies the blood flow of the presence of a frequency shift?

A

?

22
Q

Gray shades on Doppler spectrum related to two things?

A

amplitude of reflected signalnumber of blood cells creating the reflection

23
Q

Doppler Spectrum, high waveform is a high frequency or low?

A

?

24
Q

What is the Doppler Effect?

A

the change in frequency

25
Q

Difference between speed and velocity?Speed

A

magnitude (distance red blood cells travel in 1 second)

26
Q

Difference between speed and velocity?Velocity

A

Magnitude and direction

27
Q

Angle w/ Doppler/ No angle?

A

0⁰: 1.090⁰: 0180⁰: -1.0

28
Q

Primary advantage for a pulse wave Doppler?

A

select exact location(range resolution, range specificity)

29
Q

Primary advantage for continuous Doppler?

A

ability to accurately measure very high velocity

30
Q

Bidirectional, type of processing?

A

Phase quadrature or quadrature detection

31
Q

FFT used in what type of what?

A

Is a computer-based technique, is use to process both pulsed and continuous wave Doppler signals

32
Q

Velocities that color flow measures?

A

mean or average

33
Q

Autocorrelation?

A

digital technique to analyses color flow Doppler less accurate but faster than FFT

34
Q

Limitation to color flow imaging?

A

?

35
Q

Area of integration in Doppler is called?

A

?

36
Q

More accurate velocity measurement Increased sensitivity low flow

A

Large Doppler packet advantages and disadvantages?Advantages

37
Q

More time needed to acquire data Reduced frame rate Decreased temporal resolution

A

Large Doppler packet advantages and disadvantages?Disadvantages

38
Q

How to measure low flow states?

A

Power Doppler?

39
Q

Inspiration vs ExpirationInspiration

A

Diaphragm ↓Thoracic pressure ↓Abdomen pressure↓Venous return to the heart ↑Venous flow in legs ↓

40
Q

Inspiration Vs ExpirationExpiration

A

Diaphragm ↑Thoracic pressure ↑Abdomen pressure ↑Venous return to the heart ↓Venous flow in legs ↑

41
Q

Venous pressure is low, pressure in veins?

A

Low

42
Q
  1. What happens to shape of veins when pressure increases?
A

becomes circular (gets larger)

43
Q

Hydrostatic pressure when standing

A

Ankle 140 mmHg, Far below heart level, 100mmHg , 240mmHg (140 + 100) Knee, 140mmHG, Somewhat below heart