Q

What should be done once the first two parallel cuts of the trench are made?

A. Slice the length of the trench into shorter sections
B. Create another section of inspection holes
C. Begin to pull the entire length from the roof
D. Push the ceiling down into the building below

A

A> Slice the length of the trench into shorter sections

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What part of the double hung window presents a dangerous effect for the firefighter?

A. Bottom windowsill
B. Sash in the middle
C. Glass
D. Overhand

A

B. Sash in the middle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Where is the fan placed during positive pressure ventilation operations?

A. In the fire room
B. Outside the structure
C. On the fire floor
D. In a window

A

B. Outside the structure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What can be examined to determine if the fire is about to enter the cockloft?

A. Eaves
B. Skylight
C. Venturi
D. Soil pipe

A

D. Soil pipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the maximum distance above the roof that the operator should allow a spinning blade or chain to be lifted?

A. 6 inches
B. 8 inches
C. 4 inches
D. 2 inches

A

A. 6 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Which statement about a rain roof is correct?

A. Fire will vent from an inspection cut quickly
B. The added weight was not designed into the original roof supports
C. More heat will be reported from the roof than is present in the building
D. Sudden collapse of the roof will occur without warning

A

B. The added weight was not designed into the original roof supports

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What material is the Insulspan panel constructed from?

A. Fiberglass
B. Plastic
C. OSB
D. Styrofoam

A

D. Styrofoam

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the most logical place to cut off an extending fire in an H type building?

A. Throat
B. main building
C. Head
D. Exposure

A

A. Throat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What serves as an insulator from the sun’s heat in the summer and the cold during the winter in an old style flat roof?

A. Cockloft
B. asphalt covering
C. Ceiling
D. Top floor

A

A. Cockloft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What needs to be controlled at the fireground to win the battle?

A. Ignition source
B. Chemical reaction
C. Oxygen
D. Fuel

A

C. Oxygen

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What event needs to happen before the roof crew pulls the open trench?

A. Fire shows in the main vent hole on the fire side
B. Fire shows in the examination holes on the fire side
C. Fire shows in the trench cuts
D. Fire shows in the inspection holes on the safe side

A

B. Fire shows in the examination holes on the fire side

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What type of feel does the inverted roof have normally underfoot?

A. Sinking
B. Spongy
C. Arched
D. Solid

A

B. Spongy

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Which statement about horizontal ventilation is NOT correct?

A. It costs less
B. It is easier to perform
C. It is faster
D. It uses more resources

A

D. It uses more resources

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the key factor when distinguishing between venting for life and venting for fire?

A. Timing
B. Effect
C. Location
D. Amount

A

A. Timing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the answer when serious fire is in the void spaces of a building?

A. Horizontal ventilation
B. PPV
C. Vertical ventilation
D. Total ventilation

A

D. Total ventilation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What can the bulkhead door be used for when venting a skylight?

A. Failsafe
B. Ramp
C. Marker
D. Breaking tool

A

B. Ramp

17
Q

Which of the following fire locations would be the least likely to benefit from horizontal ventilation?

A. First floor of the building
B. Cockloft fire
C. Attic fire
D. Floor directly below the roof

A

A. First floor of the building

18
Q

In which location would a trench cut not generally be a beneficial undertaking?

A. Taxpayer
B. Multi winged hospital
C. L type building
D. Garden type apartments

A

A. taxpayer

19
Q

What is considered to be the most effective and efficient way to prevent horizontal fire gas spread in most cases?

A. Let the gas continue on its upward journey
B. Build a fire resistive partition
C. Blow it out of the window in its path
D. Position a countering hose stream

A

A. Let the gas continue on its upward journey

20
Q

What potential is being increased with the “green building” movement?

A. backdraft explosion
B. Rollover situation
C. Flashdraft event
D. Flashover occurance

A

A. Backdraft explosion

21
Q

What is the first thing to consider when making the ventilation cut in the flat roof?

A. need for backup
B. Size of the fire
C. Means of escape
D. Size of the hole

A

C. Means of escape

22
Q

Which statement about ways to determine the most likely direction of fire spread is correct?

A. Fastest from high to low points
B. Always moves away from the hoselines
C. Downwind side when wind currents are present
D. Towards the lower fuel load

A

C. Downwind side when wind currents are present

23
Q

What is a positive aspect of the Insulspan panels?

A. The panels are supported with many joists
B. There is no common cockloft extending down
C. There is a natural resistance to fire spread
D. the panels being used are not very thick

A

B. There is no common cockloft extending down

24
Q

Which is usually the most suitable ventilation to use in most fires in house and similar size structures?

A. Chimney
B. Window
C. Wall
D. Roof

A

B. Window

25
Q

What should be the first priority at the fire scene?

A. Designation of an interior search team
B. Placement of the initial attack hoseline
C. Assignment of the exterior ventilation team
D. Recon the immediate fire area

A

B. Placement of the initial attack hoseline

26
Q

What should be done last when going to the roof to vent a large area flat roof building?

A. Vent the top floor windows
B. Evaluate wind direction
C. Cut open the roof
D. Vent vertical shafts

A

C. Cut open the roof

27
Q

What is the minimum number of ways off the roof you should have?

A. Two
B. Four
C. Three
D. One

A

A. Two

28
Q

Which of the following is NOT a correct statement about factors to consider when deciding to vent?

A. Things will get better immediately when the space is vented
B. You must have an idea of the progress of fire control
C. Breaking glass is not something that can be reversed
D. Generally venting for fire should begin just as the hoseline begins its attack

A

A. Things will get better immediately when the space is vented

29
Q

How should firefighters on the roof proceed if vision is obscured and heat or fire is being driven towards them?

A. Hop
B. Run
C. Shuffle
D. Crawl

A

D. Crawl

30
Q

What does venting for life demand be done?

A. Get PPV in place quickly
B. Delay extinguishment
C. Take out the windows
D. Open the roof

A

C. Take out the windows

31
Q

What is the most common vertical artery to move fire gases through?

A. Staircase
B. Garbage chute
C. Pipe chase
D. Wall voids

A

A. Staircase

32
Q

What is a quick way to get water onto the fire that is in the second cockloft space when a rain roof is present?

A. Sprinkler system
B. hoseline from the interior
C. Cellar nozzle
D. Standpipe

A

C. Cellar nozzle

33
Q

What is the most serious drawback of using PPV?

A. Missing void spaces in a building
B. Pushing fire out of the roof openings
C. Fanning a smoldering fire into a large flame
D. Hiding a smoldering fire in a room

A

C. Fanning a smoldering fire into a large flame

34
Q

Which of the following is NOT a drawback of using hose stream for ventilation?

A. Cannot be used in areas of limited water supply
B. Should not be used in areas where the water will freeze on the ground
C. It must only be used at larger fires
D. There is a chance of flare up of the material

A

D. There is a chance of flare up of the material

35
Q

Approximately what distance from the main vent hole should the trench be places?

A. 20-25 feet
B. 15-20 feet
C. 25-30 feet
D. 30-35 feet

A

A. 20-25 feet

36
Q

What is used to hold each piece of the inverted roof in place?

A. Pins
B. Gusset plates
C. Gravity
D. Ropes

A

C. Gravity

37
Q

What should be completed before the trench cut is made?

A. Secondary vent hole
B. Vent all windows
C. main vent hole
D. Puncture holes

A

C. Main vent hole

38
Q

What tends to fail first on an older style flat roof?

A. Roof boards
B. Support beams
C. Tar paper
D. Cockloft ceiling

A

A. Roof boards