Test 12 Flashcards
Which consideration about the floor assemblies in a high rise building would lead to the potential for multistory collapse?
A. Solid reinforced concrete
B. Reinforced masonry
C. Overloaded floors
D. Post tensioned floors
C. Overloaded floors
What are both side of the fire barrier exposed to when they have been placed above the midpoint of a room?
A. Fire coming under the doors
B. Fire coming around the walls
C. Fire coming out the windows
D. Fire coming from the attic
C. Fire coming out the windows
What did the development of fluorescent lights and air conditioning remove the limits on in the modern high rise building?
A. Interior trim
B. Window size
C. Building height
D. Floor area
D. floor area
Which of the following is NOT of assistance to protect the patients when dealing with fire in a hospital?
A. Firefighters
B. Patients
C. Building
D. Staff
B. Patients
Which of the following is an exception to the attacking from the uninvolved toward the involved rule?
A. Living room
B. Attached garage
C. Attic space
D. Exterior panel
B. Attached garage
What happens when solid shelves are put in place in warehouses?
A. Generates a low flame spread
B. Allows stock to fall
C. Contains the fire
D. Blocks sprinkler spray
D. Blocks sprinkler spray
What can be used in the rack storage warehouse for fire suppression that will allow warehouse owners the flexibility to move the racks?
A. Automated response mechanical equipment
B. Ceiling mounted sprinkler systems
C. Early suppression/fast response sprinklers
D. In rack sprinklers
C. early suppression/ fast response sprinklers
Which type of construction is NOT acceptable for the covered mall building under recent building codes?
A. Type lV
B. Type V
C. Type lll
D. Type ll
B. Type V
What classification is usually given to the warehouse?
A. Fireproof
B. Noncombustible
C. Fire resistive
D. Combustible
B. Noncombustible
What has the tenement of ordinary construction come to mean today?
A. High value contents
B. substandard housing
C. Renovated interiors
D. Mercantile structures
B. Substandard housing
What percentage of exits stairwells were allowed to terminate in the building under model codes for years?
A. 50%
B. 70%
C. 40%
D. 60%
A. 50%
Which type of construction are the self storage buildings when they are single story drive up design?
A. Type l
B. Type lll
C. Type lV
D. Type V
B. Type lll
What is used to prevent condensation in the attic?
A. Vents
B. Gypsum
C. Bridges
D. Voids
A. Vents
What does the contemporary construction strip mall use for exterior walls?
A. Wood
B. Masonry
C. Concrete block
D. Steel
C. Concrete block
What were vertical shafts in Pre-wwll high rise buildings enclosed in?
A. Brick veneer
B. Solid masonry
C. Steel
D. Plywood
B. Solid masonry
How many floors below the fire floor should occupants be moved if they will not be completely evacuated out of the building?
A. Five
B. Two
C. Four
D. Three
A. Five
What should the fire department insist upon regarding the smoke management system?
A. Written waiver from the building owners
B. Written documentation for the system
C. Demonstrations of the system’s capabilities
D. Personal instructions on operations
B. Written documentation for the system
What must be used to protect exposures from radiant heat around and near a trench cut in a row house?
A. Dirt
B. Air flow
C. Water
D. Foam
C. Water
How often are codes rewritten and reissued?
A. Every 5 years
B. Every 3 years
C. Every 2 years
D. Every 4 years
B. every 3 years
What is typically the minimum fire department reaction time?
A. 10 minutes
B. 20 minutes
C. 5 minutes
D. 15 minutes
B. 20 minutes