Q

When performing a chest x-ray, which of these areas are most important to shield?

A

Gonads

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the first step in gonadal protection?

A

Collimation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the first step to the TJC 10-step QA program?

A

Assign responsibility

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

For the centering SID QC test, the actual center of the x-ray beam, must align to the centering indicator by _____ of the SID.

A

1%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the equation for the kVp reproducibility QC test?

A

(Exposure 1-Eposure 2)/Exposure 1= %

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

This formula is used during which QC test: (Exposure 1 mAs-Exposure 2 mAs)/ Exposure 1 mAs=?

A

Exposure Linearity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The following exposures were acquired on the radiographic machine. If testing for exposure linearity, is the machine compliant?
100 kVp, 10 mAs, 1.0 ugy
100 kVp, 20 mAs, 2.1 ugy
100 kVp, 30 mAs, 3.6 ugy
100 kVp, 40 mAs, 4.2 ugy

A

No, this machine is not compliant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When testing the CR units, all detectors must be calibrated to

A

Just the other detectors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Spatial resolution if the IR is tested using which tool?

A

Lines pair

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

A CR cassette is exposed using mAs at 65 kVp and the resulting exposure indicator is 202. The same cassette is exposed using the same technique and processes on a different reader, and the resulting exposure indicator is 435. This is a quality control issue related to?

A

Reader calibration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

For the collimation SID QC test, the light field must align with the x-ray field collimation within +/- _____ of the SID.

A

2%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

For the exposure time and AEC QC test, the actual exposure time must be within +/- ______ of indicated exposure time.

A

5%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

For the exposure time and AEC QC test, if I set my exposure time to 100ms, an acceptable exposure time to pass this test would be

A

95ms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

T/F: It is okay to repeat an exposure to improve an acceptable image.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When discussing the kVp calibration QC test, how much tube potential variance is allowed when the assigned technique for an exposure is 70 kVp?

A

+/- 3.5 kVp