TC- Turbine Cooling Water Flashcards
What is the capacity of each TC pump?
100%
Where are the TC pumps located?
100’ Turbine Building North East end
Where can the pumps be started from?
Normally from Control Room
Can be started locally at the breaker
What is normal TC system header pressure?
105 Psig
What happens if header pressure drops to 55 psig?
Standby pump will auto start
What is TC maximum allowed temperature? What is the Hi-alarm setpoint?
105F
120F
What are the TC pump power supplies?
‘A’ – NBN-S01
‘B’ – NBN-S02
What is the capacity of the TC heat exchangers?
100% each
What is the heat sink for TC?
PW system
Where are the TC HXs located?
The north yard just north of the Turbine building
What is the purpose of the TC Surge Tank?
Accommodates changes in system volume due to temperature changes
Provides NPSH for the TC pumps
Provides means of detecting leakage into or out of the TC system
Where is the Surge Tank located? What is its capacity?
140’ Turbine Building above the TC pumps
500 gallons
Why is Nitrogen used in the Surge Tank? What is the nitrogen pressure kept at? How else is the surge tank protected?
To prevent oxygen intrusion that could lead to corrosion
~25psi
over and under pressure protection
local level and pressure indication
What system provides makeup water to the TC surge tank? What is the maintained level band?
Demineralized Water
45-51”
Where is the TC Chem Add Tank located? What is the capacity?
100’ turbine building just north of the pumps
11 gallons