Sys 2 Flashcards
Primary servos
Laterl- left
Aft
Fwd
SAS
Yaw
Roll
Pitch - box
Boosted controls
Collective
Yaw
Pitch
Trim
Pitch roll yaw collective
Five cons where backup hydro will come on
Res 1 low, hyd pump 1, t/r servo 1, hyd pump 2, apu accum low
Inner loop
SAS
Dynamic stability
Short term inner loop sas fast response
Outer loop
FPS & trim long term full authority static stability
Static stability
FPS and trim
How long is the hydraulic logic open? Vs the main AC generator?
This valve is held open by the hydraulic logic module for 3 to 5 seconds when either the APU generator or external power is supplying power, or for 0.5 second when the main AC generators are supplying power.
Is ng / Np connected mechanically?
No
Np and NR connected mechanically ?
Yes
Engine Abort Start Criteria
No TGT rise within 45 seconds, No Np1 or Np2 within 45 seconds, No Eng Pressure 1 or 2 within 45 seconds, ENG Starter Caution off before reaching 52% NG, TGT rises above 851 Degrees.
Trim is solely implemented by ?
FCC 2
Electromagnetic actuators -3
Electrohydraulic -1
3- roll, yaw, collective
1- pitch
Tail rotor
cAnted 20*, produces 2.5 % lift
TAIL ROTOR QUAD FAIL
Can be one or both cables broken, can tell by adjusting collective
Will work between 25-145 kts and fix pitch at 10.5 fix pitch if both broken
One broke? U good
Main transmission has how many degree fwd tilt?
3 degrees
What are the three priorities of power? (Electrical)
First Priority – Main Generators. If there is at least one Main Generator operating, with one exception, the APU Generator or the External Power Receptacle will not be able to power the system.
- Second Priority – APU Generator. If the APU Generator is operating the External Power Receptacle will not be able to power the system.
Third Priority – External Power Receptacle. A ground power unit (GPU) attached to the External Power Receptacle will only be able to power the aircraft if there are no generators operational.
How is the main generator cooled?
Each Main Generator is rated at 30/45 KVA,
is cooled by transmission oil,
and provides 115/200 VAC, 3 phase, 400 Hz power
How is the APU cooled?
The APU Generator is rated at 20/23.8 KVA,
is air cooled
and provide 115/200 VAC, 3 phase, 400 Hz power
How many generators does it take to run the blade de ice?
Takes two generators
Or APU can run with the help of another generator but not by itself
CHIP L/R INPUT MDL
Idle
CHIP L/R ACC MDL
LAND ASAP
If you’re just down to battery power how long do you have ?
Provide uninterrupted emergency power for 15 minutes (12 minutes at night with the search light on)
GEN 1 and 2 FAIL caution
The generator fail cautions do not appear unless AC power is available. The lights are powered by the DC Primary busses.
During run-up, both lights should go off above 97% Nr.
iii. Appears whenever generator output is interrupted.
iv. The other generator will then supply power to all busses.
v. Disappears with a successful generator test.
APU GEN ON
Comes on when APU is the sole source of of Ac Pwr
Each generator has a primary and alternate bearing, how many flight hours will the alternative provide if you have a GEN BRG 1/2 FAIL?
10, alternate bearing provides
CONV 1 (or 2) FAIL : converter 1 or 2 has no output
Do nothing, especially do not turn off the battery switch Or you’ll lose power
Turning No. 1 battery switch off will result in loss of No. 1 BATT Bus and No. 1 DC ESS bus.
AC REF BUS DEGRAD- advisory light
Appears when one of the two auto-transformers supplying bus power has failed.
ADVISORY LIGHT, when transformer has failed
dual generator failure
will result in loss of all ac powered systems,
Look for ac ref bus degrade In advisory
- Airspeed — Adjust (80 KIAS or less).
- GENERATORS NO. 1 and NO. 2 switches— RESET; then ON.
If electrical power is not restored:
- GENERATORS NO. 1 and NO. 2 switches— OFF.
- MCUs and ECS– OFF prior to EMER APU START.
- EMER APU START.
- LAND AS SOON AS PRACTICABLE.
- If APU GEN ON advisory extinguishes, ensure MCUs and ECS – OFF prior to resetting the APU generator.
GEN 1 FAIL or GEN 2 FAIL Caution Appears
- Affected GENERATORS switch — RESET; then ON.
If caution remains:
- Affected GENERATORS switch — OFF.
With a dual converter failure which BUS will not be hot?
Primary busses
You only have 15 min left on the battery power and 12 at night
What drives LRUs on accessory gearbox?
NG
The HMU operates what part of the compressor section?
Variable guide veins