SY212 Flashcards
True or false? The AIR COND switch is available in both cockpits and is used to activate the air
conditioner compressor.
False. The AIR COND switch is located only in the front cockpit on the environmental control panel.
True or false? Placing the vent control lever in the CANOPY position opens the defog valve.
False. The defog valve is opened by placing the DEFOG switch in the ON position.
Which cockpit control and duct component controls whether warm bleed air is routed to the
footwarmers or defog outlets?
The front cockpit vent control lever adjusts the position of the cockpit selector valves to
route warm air to either the footwarmers or the defog outlets.
True or false? The Temperature Control Switch Knob on the Environmental Control Panel controls
the temperature of both heating and defogging air.
True. The switch knob controls the position of the heat exchanger bypass valve which
determines the temperature of air for both heating and defogging.
The safety valve will open to relieve excess cockpit pressure, regulating the pressure at 4.0
psi.
If cockpit pressure differential exceeds 4.0 psi, the ∆P regulator sends a signal to the safety outflow
valve. What does the safety outflow valve do?
To provide enhanced protection against possible birdstrikes, the forward windscreen and front
transparency are thicker than the rear transparency. These two transparencies have been designed to withstand what type of birdstrike?
A 4-pound birdstrike at up to 270 KIAS.
With the TEMP CONTROL switch in the AUTO position, the bypass valve diverts a portion of the
warm bleed air around the heat exchanger to be mixed with cooled air downstream of the heat
exchanger. This system automatically controls cockpit temperature between what temperature?
60° and 90° Fahrenheit
Above what temperature will the amber OBOGS TEMP annunciator light?
If the temperature in OBOGS ducting exceeds
200° Fahrenheit.
Which annunciator will light if the inflow air temperature exceeds 300° Fahrenheit?
DUCT TEMP Annunciator
Above what temperature does the exchanger bypass valve move to full closed and thereby forcing maximum bleed air through the heat exchanger.
At a temperature in excess of 165° F
A cockpit pressure differential of 3.6±0.2 psi is normally reached at what altitude?
18,069 feet
True or false? Pressure for the anti-G system is supplied from an electrically driven pump.
False. System pressure is supplied by the engine right side bleed air port.
Which oxygen pressure regulator concentration lever position supplies the highest possible oxygen
concentration?
The MAX position
When is the canopy pressure seal inflated?
The seal is automatically inflated when bleed air inflow is available and weight is off the
right main landing gear.
True or false? Aircraft electrical power must be available for the canopy fracturing system to
function.
False. The CFS requires no electricity to function.