Switches, Outlets Flashcards
For a common area:
What is the height requirement for switches and plugs when reaching over an obstruction (of 34”) that is under 10” in depth?
They must be no higher than 48”
For a common area:
What is the height requirement for switches and plugs when reaching over an obstruction (of 34”) that is over 10” in depth with a parallel approach?
- Local Code
They must be no higher than 46” and no deeper than 25-1/2”.
What are the requirements for an outlet on the back wall of a desk that only has a forward approach?
It must no higher than 44” and the reach must be 25” or less.
What are the requirements for an outlet on the back wall of a desk that has a parallel approach?
It must be no higher than 46” and the reach must be 25-1/2” or less.
What electrical switches and controls are not covered by FHAG?
1) Circuit breakers
2) Appliance controls
3) Outlets dedicated to certain appliances