SUBELEMENT G0 – ELECTRICAL AND RF SAFETY Flashcards

1
Q

G0A01 (A)

What is one way that RF energy can affect human body tissue?

A

A. It heats body tissue

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

G0A02 (D)
Which of the following properties is important in estimating whether an RF signal exceeds the maximum permissible exposure (MPE)?

A

A. Its duty cycle
B. Its frequency
C. Its power density
D. All of these choices are correct

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

G0A03 (D) [97.13(c)(1)]

How can you determine that your station complies with FCC RF exposure regulations?

A

A. By calculation based on FCC OET Bulletin 65
B. By calculation based on computer modeling
C. By measurement of field strength using calibrated equipment
D. All of these choices are correct

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

G0A04 (D)

What does “time averaging” mean in reference to RF radiation exposure?

A

D. The total RF exposure averaged over a certain time

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

G0A05 (A)

What must you do if an evaluation of your station shows RF energy radiated from your station exceeds permissible limits?

A

A. Take action to prevent human exposure to the excessive RF fields

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

G0A06 (D)

What precaution should be taken when installing a ground-mounted antenna?

A

D. It should be installed such that it is protected against unauthorized access

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

G0A07 (A)

What effect does transmitter duty cycle have when evaluating RF exposure?

A

A. A lower transmitter duty cycle permits greater short-term exposure levels

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

G0A08 (C)
Which of the following steps must an amateur operator take to ensure compliance with RF safety regulations when transmitter power exceeds levels specified in FCC Part 97.13?

A

C. Perform a routine RF exposure evaluation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

G0A09 (B)

What type of instrument can be used to accurately measure an RF field?

A

B. A calibrated field strength meter with a calibrated antenna

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

G0A10 (D)
What is one thing that can be done if evaluation shows that a neighbor might receive more than the allowable limit of RF exposure from the main lobe of a directional antenna?

A

D. Take precautions to ensure that the antenna cannot be pointed in their direction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

G0A11 (C)

What precaution should you take if you install an indoor transmitting antenna?

A

C. Make sure that MPE limits are not exceeded in occupied areas

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

G0A12 (B)

What precaution should you take whenever you make adjustments or repairs to an antenna?

A

B. Turn off the transmitter and disconnect the feed line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

G0B01 (A)
Which wire or wires in a four-conductor connection should be attached to fuses or circuit breakers in a device operated from a 240 VAC single phase source?

A

A. Only the two wires carrying voltage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

G0B02 (C)

What is the minimum wire size that may be safely used for a circuit that draws up to 20 amperes of continuous current?

A

C. AWG number 12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

G0B03 (D)

Which size of fuse or circuit breaker would be appropriate to use with a circuit that uses AWG number 14 wiring?

A

D. 15 amperes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

G0B04 (A)

Which of the following is a primary reason for not placing a gasoline-fueled generator inside an occupied area?

A

A. Danger of carbon monoxide poisoning

17
Q

G0B05 (B)
Which of the following conditions will cause a Ground Fault Circuit Interrupter (GFCI) to disconnect the 120 or 240 Volt AC line power to a device?

A

B. Current flowing from one or more of the voltage-carrying wires directly to ground

18
Q

G0B06 (D)

Why must the metal enclosure of every item of station equipment be grounded?

A

D. It ensures that hazardous voltages cannot appear on the chassis

19
Q

G0B07 (B)

Which of these choices should be observed when climbing a tower using a safety belt or harness?

A

B. Confirm that the belt is rated for the weight of the climber and that it is within its allowable service life

20
Q

G0B08 (B)

What should be done by any person preparing to climb a tower that supports electrically powered devices?

A

B. Make sure all circuits that supply power to the tower are locked out and tagged

21
Q

G0B09 (D)

Why should soldered joints not be used with the wires that connect the base of a tower to a system of ground rods?

A

D. A soldered joint will likely be destroyed by the heat of a lightning strike

22
Q

G0B10 (A)

Which of the following is a danger from lead-tin solder?

A

A. Lead can contaminate food if hands are not washed carefully after handling the solder

23
Q

G0B11 (D)

Which of the following is good practice for lightning protection grounds?

A

D. They must be bonded together with all other grounds

24
Q

G0B12 (C)

What is the purpose of a power supply interlock?

A

C. To ensure that dangerous voltages are removed if the cabinet is opened

25
Q

G0B13 (A)

What must you do when powering your house from an emergency generator?

A

A. Disconnect the incoming utility power feed

26
Q

G0B14 (C)

Which of the following is covered by the National Electrical Code?

A

C. Electrical safety inside the ham shack

27
Q

G0B15 (A)

Which of the following is true of an emergency generator installation?

A

A. The generator should be located in a well-ventilated area