Steam Boilers Module 15 Session 12 Flashcards

1
Q
Deposits of calcium and magnesium carbonates on the boiler heating surface cause \_\_\_\_\_\_\_\_\_\_\_\_.
A. Scale
B. Oxygen pitting
C. Caustic embrittlement
D. Carryover
A

A. Scale

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
Priming is dangerous and could lead to \_\_\_\_\_\_\_\_\_\_\_\_ hammer.
A. Steam
B. Water
C. Gas
D. Air
A

B. Water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
Small amounts of water that leave the boiler with the steam is called \_\_\_\_\_\_\_\_\_\_\_\_.
A. Superheated steam
B. Saturated steam
C. Carryover
D. Condensate
A

C. Carryover

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Closer control of boiler water chemical concentrations is maintained by ____________.
A. Surface blowdowns
B. Bottom blowdowns
C. A combination of surface and bottom blowdowns
D. Continuous blowdowns

A

D. Continuous blowdowns

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
Cracking of the boiler metal along the seams and tube ends is caused by \_\_\_\_\_\_\_\_\_\_\_\_.
A. scale
B. Oxygen pitting
C. Caustic embrittlement
D. Carryover
A

C. Caustic embrittlement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Scale buildup on the water side of a steam boiler is caused by ____________.
A. An impure water supply
B. Scale in the raw Water
C. Improper boiler water treatment
D. Scale is found only on the fire side of a boiler

A

C. Improper boiler water treatment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
A direct cause of overheating of the boiler tubes is \_\_\_\_\_\_\_\_\_\_\_\_.
A. Soot formation
B. Overfiring
C. Insufficient air
D. Scale formation on the tubes
A

D. Scale formation on the tubes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q
Boiler water having high alkalinity could develop \_\_\_\_\_\_\_\_\_\_\_\_.
A. Scale
B. Oxygen pitting
C. Caustic embrittlement
D. Warping
A

C. Caustic embrittlement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
Oxygen in the boiler will cause \_\_\_\_\_\_\_\_\_\_\_\_.
A. Scale
B. Pitting of boiler metal
C. Caustic embrittlement
D. Carryover
A

B. Pitting of boiler metal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q
The cold lime-soda process softens the boiler water at \_\_\_\_\_\_\_\_\_\_\_\_.
A. Temperatures of 212°F or above
B. Ambient temperature
C. Temperatures below 32°F
D. A high, controlled pressure
A

B. Ambient temperature

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q
The hot lime-soda process is performed above \_\_\_\_\_\_\_\_\_\_\_\_.
A. 180 °F
B. 212 °F
C. 250 °F
D. 298 °F
A

B. 212 °F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The ion exchange (Zeolite) process is performed at ____________ temperature.
A. Ambient
B. A low
C. A high

A

A. Ambient

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q
Automatic blowdown systems are limited to a maximum of \_\_\_\_\_\_\_\_\_\_\_\_ and 250 psig.
A. 298 °F
B. 354 °F
C. 368 °F
D. 392 °F
A

No Answer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q
The frequency of blowing down a steam boiler is best ascertained by the \_\_\_\_\_\_\_\_\_\_\_\_.
A. Chief engineer
B. Boiler inspector
C. Daily testing of boiler water
D. Plant load
A

C. Daily testing of boiler water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly