Steam Boilers Module 15 Session 12 Flashcards
Deposits of calcium and magnesium carbonates on the boiler heating surface cause \_\_\_\_\_\_\_\_\_\_\_\_. A. Scale B. Oxygen pitting C. Caustic embrittlement D. Carryover
A. Scale
Priming is dangerous and could lead to \_\_\_\_\_\_\_\_\_\_\_\_ hammer. A. Steam B. Water C. Gas D. Air
B. Water
Small amounts of water that leave the boiler with the steam is called \_\_\_\_\_\_\_\_\_\_\_\_. A. Superheated steam B. Saturated steam C. Carryover D. Condensate
C. Carryover
Closer control of boiler water chemical concentrations is maintained by ____________.
A. Surface blowdowns
B. Bottom blowdowns
C. A combination of surface and bottom blowdowns
D. Continuous blowdowns
D. Continuous blowdowns
Cracking of the boiler metal along the seams and tube ends is caused by \_\_\_\_\_\_\_\_\_\_\_\_. A. scale B. Oxygen pitting C. Caustic embrittlement D. Carryover
C. Caustic embrittlement
Scale buildup on the water side of a steam boiler is caused by ____________.
A. An impure water supply
B. Scale in the raw Water
C. Improper boiler water treatment
D. Scale is found only on the fire side of a boiler
C. Improper boiler water treatment
A direct cause of overheating of the boiler tubes is \_\_\_\_\_\_\_\_\_\_\_\_. A. Soot formation B. Overfiring C. Insufficient air D. Scale formation on the tubes
D. Scale formation on the tubes
Boiler water having high alkalinity could develop \_\_\_\_\_\_\_\_\_\_\_\_. A. Scale B. Oxygen pitting C. Caustic embrittlement D. Warping
C. Caustic embrittlement
Oxygen in the boiler will cause \_\_\_\_\_\_\_\_\_\_\_\_. A. Scale B. Pitting of boiler metal C. Caustic embrittlement D. Carryover
B. Pitting of boiler metal
The cold lime-soda process softens the boiler water at \_\_\_\_\_\_\_\_\_\_\_\_. A. Temperatures of 212°F or above B. Ambient temperature C. Temperatures below 32°F D. A high, controlled pressure
B. Ambient temperature
The hot lime-soda process is performed above \_\_\_\_\_\_\_\_\_\_\_\_. A. 180 °F B. 212 °F C. 250 °F D. 298 °F
B. 212 °F
The ion exchange (Zeolite) process is performed at ____________ temperature.
A. Ambient
B. A low
C. A high
A. Ambient
Automatic blowdown systems are limited to a maximum of \_\_\_\_\_\_\_\_\_\_\_\_ and 250 psig. A. 298 °F B. 354 °F C. 368 °F D. 392 °F
No Answer
The frequency of blowing down a steam boiler is best ascertained by the \_\_\_\_\_\_\_\_\_\_\_\_. A. Chief engineer B. Boiler inspector C. Daily testing of boiler water D. Plant load
C. Daily testing of boiler water