St Monica's Church Hall Flashcards

1
Q

In Construction Technology, you mention demolition - what was the cost, duration, for this and how measure?

A

Demolition:
£130k (1930 building; traditional - red brick, concrete surrounds, pitched roof, timber windows; 4 storeys) 800m2 (£170/m2)
Measure - quote

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

In Construction Technology, you mention the following - please tell me costs, duration, for these and how measured:
Steel frame
Flat roof
Roof lights
Glazed curtain walling
Foldable acoustic partition
Floor finishes

External wall (brick/block cavity)
Single skin internal block walls

A

Steel frame £170k (1,367m2, £122/m2)
Protection £50k (1,367m2, £40/m2)

Flat roof £125k (650m2, £200/m2)
Roof lights £15k (5 nr, £3k/nr)
Glazed curtain walling £60k (80m2, £750/m2)
Foldable acoustic partition £60k (£750/m2)
Floor finishes £10k (250m2, £40/m2)
External wall (brick/block cavity) £160k (650m2; £250/m2)
Single skin internal block walls £50k (850m2, £60/m2)
Foundations - £90k inc excav; strip (406m3, £250/m3)
Ground floor slab - £150k (650m2, £250/m2)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

In QCCW, you mention a cost plan - what was the total estimated costs for this? Some of the works categories? Costs including measurement units? How obtain costs from BCIS, Spons, in-house data on these? How did you go about obtaining quotes from several suppliers (did you estimate possible costs in advance?).

A

Cost estimate (where obtain rates/costs):
Steel - expensive and fluctuates! Check latest market data (£/tonne)
Acoustic partition - quote!
Flat roof - in house
Curtain walling - in house
Finishes - in house
M&E - GIA rate (rate from in house)
Foundations - in house

Obtaining quotes from suppliers (and preparing for anticipation of costs):
Demolition
Acoustic partition

Details on Acoustic Partitions:
Building Regulation Standards: Fire safety (B) short (30 minutes), medium (60 minutes) or long (120 minutes). ; sound insulation (E) The requirement for wall soundproofing of airborne sound pollution in purpose-built dwellings is 45 dB. The requirement for floors and ceilings in purpose-built dwellings of airborne sound also sits at 45 dB. However, there is also a requirement of 62 dB for impact sound (such as walking on floorboards).; structural ability (A) - structural engineer??.
Material: ACOUSTIC - Aluminium frame with double skin cladding of 12 mm, high density particleboard. Choice of panel finishes from manufacturer’s standard range, Standard laminate, Rw 52 dB Weight: 42 kg/m²; Thickness: 80 mm with exposed edge trims.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly