SRP Equipment Flashcards
Single phase dead front pad mount transformer - Dist map
Single phase dead front pad mount transformer - Schematic map
Single phase dead front pad mount transformer - Circuits map
Single phase dead front pulling enclosure - Dist map
Single phase dead front pulling enclosure - Schematic map
Single phase dead front pulling enclosure - Circuits map
Single phase dead front fused enclosure - Dist map
Single phase dead front fused enclosure - Schematic map
Single phase dead front fused enclosure - Circuits map
Three phase dead front pad mount transformer - Dist map
Three phase dead front pad mount transformer (L: Loop) - Schematic map
Three phase dead front pad mount transformer - Circuits map
Dead front pad mount fusing cubicle - Dist map
Dead front pad mount fusing cubicle - Schematic map
Dead front pad mount fusing cubicle - Circuits map
Three phase dead front pad mount gang switch - Dist map
Three phase dead front pad mount gang switch - Schematic map
Three phase dead front pad mount gang switch - Circuits map
Three phase dead front pad mount tapped enclosure - Dist map
Three phase dead front pad mount tapped enclosure - Schematic map
Three phase dead front pad mount tapped enclosure - Circuits map
Three phase dead front pad mount intellirupter recloser - Circuits map
Three phase dead front pad mount smart gang switch - Dist map
Three phase dead front pad mount smart gang switch - Schematic map
Three phase dead front pad mounted smart gang switch - Circuits map
Three phase dead front pad mounted controllable gang switch - Dist map
Three phase dead front pad mounted controllable gang switch - Schematic map
Three phase dead front pad mount controllable gang switch - Circuits map
Three phase dead front pad mount 4 way gang switch - Dist map
Three phase dead front pad mount 4 way gang switch - Schematic map
Three phase dead front pad mount 4 way gang switch - Circuits map
Three phase dead front pad mount pulling enclosure - Dist map
Three phase dead front pad mount pulling enclosure - Schematic map
Three phase dead front pad mounted pulling enclosure - Circuits map
Three phase dead front pad mounted capacitor bank - Dist map
Three phase dead front pad mounted capacitor bank - Schematic map
Three phase dead front pad mounted capacitor bank - Circuits map
Three phase live front pad mount transformer (R means radial/live front) - Schematic map
Three phase live front pad mount gang switch - Dist map
Three phase live front pad mounted gang switch - Schematic map
Three phase live front pad mounted gang switch - Circ map
Three phase live front pad mount blades switch - Dist map
Three phase live front pad mount blades switch - Schematic map
Three phase live front pad mount blades switch - Circ map
Live front pad mounted fusing cubicle - Dist map
Live front pad mount fusing cubicle - Schematic map
Live front pad mount fusing cubicle - Circ map
Below ground manhole - Dist map
Below ground manhole - Schematic map
Below ground manhole - Circ map
Above ground vault - Dist map
Above ground vault - Schematic map
Above ground vault - Circ map
Below ground vault - Dist map
Below ground vault - Schematic map
Below ground vault - Circ map
Substation manhole - Dist map
Substation manhole - Schematic map
Substation manhole - Circ map
Single phase pole riser - Dist map
Single phase pole riser - Schematic map
Single phase pole riser - Circ map
Multiple single phase pole risers - Dist map
Multiple single phase pole risers - Schematic map
Three phase gang operated load break pole riser - Dist map
Three phase gang operated load break pole riser - Schematic map
Three phase blades pole riser - Circ map
Three phase gang operated load break pole riser - Circ map
Three phase blades pole riser - Schematic map
Three phase blades pole riser - Dist map
Underground feeder (energized) three phase 500 or 750 MCM - Dist map
Underground feeder (energized) three phase 500 or 750 MCM - Schematic map
2 phase underground primary cable - Schematic map
3 phase underground primary cable - Schematic map
Single phase (A phase) underground primary cable - Schematic map
2 phase underground primary cable - Circ map
3 phase underground primary cable - Circ map
Single phase primary underground cable - Circ map
Underground service - Dist map
Underground primary cable - Dist map
Buried J-box - Dist map
Underground secondary cable -Dist map
Underground street light cable - Dist map
Abandoned underground cable - Dist map
De-energized underground primary cable - Circ map
Street light - Dist map
Overhead service wire - Dist map
Overhead secondary wire - Dist map
Overhead street light wire - Dist map
Pole to pole guy - Dist map
Dynamic open - Circ map
Dynamic close - Circ map
What is the red line depicting?
Jumpers - Circ map
Single and dual phase normal open - Circ map
Single or dual phase normal open - Schematic map
Three phase normal open - Circ map
Three phase normal open - Schematic map
Normal open three phase pad mount dead front gang switch - Circ map
Normal open three phase pad mount dead front gang switch - Schematic map
Normal open three phase overhead gang switch load break - Circ map
Normal open three phase overhead gang switch load break - Dist map
Open build point - Circ map
Close build point - Circ map
New pole riser - Circ map
New underground primary cable - Circ map
Closed (red) build points allow existing underground primary cable to be…
Abandoned
Open (green) build points allow new underground cable to be…
Energized
Abandoned underground primary cable - Schematic map
Removed pole riser - Schematic map
New pole riser - Schematic map
Dashed brown lines are….
Solid brown lines are…
New underground primary cable
Existing underground cable - Distribution map
Non-switchable pole risers - Circ map
Non-switchable pole risers - Schematic map
Fault indicators - Schematic map
Manhole - Circ map
Manhole - Schematic map
Manhole - Dist map
What does K indicate?
In conduit - Dist map
Underground street light - Dist map
Underground point of delivery - Dist map
Intellirupter programmed as a controllable switch
Intellirupter programmed as smart switch
Intellirupter programmed as a recloser
Overhead cap bank - Circ map
Overhead cap bank - Dist map
Overhead 3 pot transformer bank - Circ map
Overhead 3 pot transformer bank - Dist map
Overhead 2 pot transformer bank - Circ map
Overhead 2 pot transformer bank - Dist map
Overhead single phase transformer - Circ map
Overhead single phase transformer - Dist map
Overhead 3 phase conductor - Circ map (conductor is circuit color)
Overhead single phase primary - Circ map
2 phase overhead primary conductor - Dist map
What is green?
What is purple?
Green is 3 phase overhead primary conductor.
Purple is 3 phase overhead feeder conductor.
Dist map
3 phase overhead to underground blades - Circ map
3 phase overhead to underground blades - Dist map
3 phase overhead gang operated load break switch - Circ map
3 phase overhead gang operated non load break switch - Circ map
3 phase overhead blades - Circ map
3 phase overhead gang operated switch - Dist map
3 phase overhead gang operated switch non load break - Dist map
3 phase overhead blades - Dist map