Spooky Crash Course Flashcards
Question 3:
Units are operating at a chemical attack in a subway. Which team will establish a communications relay to the IC until relieved by the first arriving CPC equipped unit?
A: First arriving Ladder Company team 1
B: First arriving Ladder Company team 2
C: Second arriving Ladder Company team 1
D: Second arriving Ladder Company team 2
ERP Add 2 sec 6.2
In addition to directing evacuation, 2 members will be designated the back up team for team 1 and will establish a communications relay to the IC until relieved by the first arriving CPC equipped unit.
Question 17:
Units operating at a fire in an Old Law Tenement would know that ___________ shall direct and control horizontal ventilation on all floors above the fire floor.
A: 1st due ladder officer
B: 2nd due ladder officer
C: IC
D: Fire sector chief
Explanation:
The officer of the second ladder company to arrive shall direct and control horizontal ventilation on all floors above the fire floor
Lad 3 Tenements sec 3.4.2 Duties 9
Question 34:
Choose the incorrect hoseline procedure for a fire in a Rowframe.
A: An engine company, ordered to stretch a hoseline to the top floor of an exposure for purposes of extinguishing the fire in the cockloft, should take a 6 foot hook to pull ceilings
B: For a cellar fire in a Rowframe, the 1st handline was stretched via an outside entrance
C: For a cellar fire in a Rowframe, if the 1st hoseline has advanced into the cellar, and a backup line is not needed, the 2nd hoseline shall extinguish any fire on the 1st floor then proceed to the top floor
D: For a cellar fire in a Rowframe, if the first hoseline is used to cover the first floor public hall, and a back up line is not needed, the second hoseline will be stretched into the cellar via the outside cellar entrance to extinguish the fire
Rowframes p-47-48 B
Through the front door then to the cellar via the interior stairs to extinguish the fire
Question 11:
Lad 6 arrives first due and Lad 11 second due for a 6th floor fire in an 18 story project. A victim is showing from a 6th floor window and Lad 6 OV/LCC team prepares for a rescue. What is the correct location for Lad 11’s OV firefighter at this fire?
A: Team up with your LCC and assist with outside operations.
B: If the building does not have fireman service elevators, proceed to the fire floor and team up with your officer.
C: If the building does have fireman service elevators, operate the elevator since first OV FF is performing a rescue.
D: Recall all elevators, regardless of the fire floor location and whether or not FD members will use them
Explanation:
MD ch 2 sec 9.3.2 B 2
A. If outside operations are in progress, team up with your 2nd ladder chauffeur and assist with same.
Question 39:
Yellow Hydrants on Parkways and Expressways must be turned on fully at the curb valve, approximately _______ using a curb valve key.
A: 18 turns clockwise
B: 17 turns clockwise
C: 17 turns counterclockwise
D: 18 turns counterclockwise
B Explanation:
Engine Ops. ch 3 add 4 sec 2.3.3
Question 20:
Certain equipment shall be assembled in readiness and placed on company apparatus when a snow or ice emergency is imminent or Phase A or B is established. Of the following choices, which is not an accurate description of this equipment?
A: At least 6 extra lengths of 2 ½” hose, rolled or folded, on each Engine and Ladder apparatus.
B: 2 shovels.
C: Containers of salt and/or sand.
D: Chains or tow cable for pulling out stuck apparatus.
Explanation: D
Vehicle recovery strap with shackle
Also….Tire chains, spare links and link tool.
Also….Specialized hydrant connection set-up as determined by individual commanding officers.
AUC 200 3.3.3 D
Question 26:
Of the following choices, which is not in accordance with Fire Department procedures for the Iroquois Pipeline?
A: Isolation of the pipeline is vital in controlling the gas leak. Isolation duties are typically carried out by remotely shutting down valves from the Iroquois Gas Control Center.
B: The initial actions of units responding to pipeline boxes are to set up a perimeter and eliminate sources of ignition.
C: Due to the extremely high pressure found in this pipeline system, consideration shall be given to utilizing fog lines to assist in the dispersal of natural gas.
D: Except in the event of immediate threat to life or property, no valves should be opened or closed without the approval of the FDNY IC in consultation with Con Edison/Iroquois personnel
Explanation:
Natural gas is lighter than air and will naturally disperse into the atmosphere. Due to the extremely high pressure found in this pipeline system, consideration shall be given to allow escaping gas to naturally disperse into the atmosphere without the use of fog lines to assist in dispersal. The use of fog lines may actually hinder the dissipation of the gas.
AUC 150 4.5, 7.1-7.1.2
Question 23:
When units are called to the scene of an airborne
irritant incident (such as pepper spray, mace or a mace-like substance) all choices below should be adhered to except?\
A: Full firefighting gear and N95 masks will be used at all times as a minimum of protection against exposure. Transmit a 10-80 Code 1 at all airborne irritant incidents.
B: There are essentially two ways to protect the public from the effects of hazardous material discharges into the environment: evacuation and sheltering in place. In the case of airborne irritants, evacuation would be appropriate for exposed individuals, and will most likely be self-initiated.
C: In some instances, evacuation through a toxic atmosphere may actually cause more harm than good, such as removing occupants from their uncontaminated apartments and transporting them through a contaminated public hallway or staircase. In this type of situation, the decision to shelter in place would be more appropriate.
D: Controlled ventilation (mechanical or natural) of the affected areas by Fire Department personnel will facilitate rapid dissipation of the vapor cloud. Avoid moving the product to occupied areas
Explanation:
Full firefighting gear and SCBA will be used at all times as a minimum of protection against exposure. Transmit the initial 10-80 signal to alert incoming units to proceed with caution to avoid entering a contaminated area.
HM 17 2.2, 2.3, 2.5
Question 5:
As part of the Iroquois Pipeline, there is a buried manual valve designated E13A-1 outside the meter/regulating station at Food Center Drive. Of the following choices, which is incorrect regarding this valve?
A: There is a sign “FDNY Valve E-13A-1” located on the fence adjacent to the gated entrance and an additional sign opposite the valve manhole alongside the entrance road.
B: The valve stem is covered by a flush mounted valve box similar to a Con Edison manhole cover.
C: This valve requires 213 quarter turns to close.
D: There is a special manual wrench for this valve just inside the entrance gate with a sign attached identifying it
Explanation: C
This valve requires 213 FULL turns to close.
D Note: Rescue 3 carries a special hydraulic wrench for this valve and a backup hydraulic wrench is stored at the FDNY Command Post building at 500 Food Center Drive.
AUC 150 3.4.1