When adding new drives and disk access enclosures (DAEs) to a Unity system, which method will yield greater performance?
Cable 1 DAE on each available bus and then distribute additional DAEs evenly; evenly distribute flash drives across all busses
How much parity information will be written to the drives on a 1 MB aligned write to a RAID 6 4+2 LUN?
(64KB)
What is a primary purpose of the Unity CMI channel?
Mirroring of write operations
A customer has requested an all FLASH solution for their block storage and expects their load capacity to grow to 35 TB in the next 5 years. They want to minimize additional drive load due to possible metadata activity. Which system should be recommended as a solution for the customer?
U450F
What accurately describes “skew” in respect to storage systems?
Measure of the non-uniformity of data access to different address regions of storage capacity
If there are 20 drives In a RAID 1/0 striped mirror configuration, what is the maximum number of drives that could fail and still maintain data access?
10 drives if that left 1 from each pair available
What is a recommended way to ensure a Unity system is capable of supporting Snapshots?
Plan enough drives to support the additional I/O for Snapshots, in addition to the customer’s expected workload
Approximately how much initial allocated capacity is used for a new Thin LUN on a Unity system?
(1.5GB)
What is a benefit of performing prefetch?
Improves response time for sequential I/O reads
What is an advantage of ALUA in a Unity system?
(Active/Active LUN access, with load balancing across both SPs)
What is the stripe element size for Unity RAID 5 storage pools?
(256KB)
What accurately describes the performance impact to production workloads while a RAID 5 RAID Group is rebuilding after a drive failure?
(Severe, as the storage must read 1 piece of data from all remaining RAID Group members, read 1 piece of parity from all remaining RAID Group members, calculate the new data and parity, and write the new data and parity to the hot spare drive)
A customer has unused Flash drives in a Unity All-Flash system, and would like to create a new dynamic pool. They want to combine 15x SAS Flash 3 and 10x SAS Flash 4 into a dynamic pool, with RAID 5 protection. What should be the appropriate response to the customer?
(Since there are more than 13 total drives, the largest RAID 5 stripe width of 12+1 will be applied to the pool)
When expanding a Unity traditional pool, what is the preferred number of drives that should be added to any single tier?
A multiple of the preferred RAID modulus drive count for that tier
A customer is purchasing a Unity system that will host an application requiring high read and write bandwidth. Clients will connect through iSCSI. In addition to determining the appropriate model and drive complement, which two (2) options should be considered?
Determine if the SAS I/O Module will be required to meet the application bandwidth
Determine the appropriate number and type of network ports required to meet the application bandwidth
Which three (3) options accurately describe how Unity detects workload skew and optimizes for best performance?
MCC tracks cache activity and keeps most recently used data in DRAM
FAST VP calculates relative temperature for all slices in a storage pool, and moves the hottest slices to the highest-performing tier
FAST Cache tracks accesses to drive elements, identifies HDD regions that are frequently re-hit, and promotes them to Flash drives
What is the I/O size used to transfer data between a Unity NAS server and storage processor?
(Always 8 KB)
In block synchronous replication with Unity, what is the process for a host read?
(Data is verified to be consistent between the local and remote LUNs before sending the data to the host)
What is required to retrieve performance archives from a Unity system?
(Archive to CSV dump utility)
A customer has requested the appropriate Unity cache tunings for their File-based backup-to-disk solution. Which tuning should be recommended?
(Set write cache size to be twice the value of buffer cache size; give any remaining DRAM to read cache)