What fixtures need to go on a trench and what fixtures can be on a wall connected to a trench?
On Trench are fixtures with floor drains: Water heater, toilet, shower, mop sink
On wall connected to trench: Lav
Remember to list trench extension and cumulative total
Label off to the side for graders to see
How much clear space do you need in front of an electrical planel
3’
What is measured on the exit access portion? and what is the amount it shouldn’t exceed.
Where travel distance is measured
Not to exceed 250’
Occupant Load:
If fixed seats - count the amount for occ load
w/o diving arms =
booth =
18”
24”
2 exit access doorways must be provided from any space where occupancy load exceeds what?
49 for MAB
29 for S
Exceptions to the 2 exit requirement
Group R2/R3 (apt, condo) - 1 exit for occ load -20 and up to 4000SF
Exits through intervening spaces - stockroom
44” wide min
demarcated with full/partial fixed walls or sim
not more than 50% of exit access
- 3 (0.2)
0. 2 (1.5)
Stairways 0.3 (0.2)
Other Egress 0.2 (0.15)
Stairways - Occupant load 50+, Occupant load 49-
50+ - min 44” or 0.3 (0.2
49- - 36” min
Handrails cannot project more than what?
Tread and riser?
4.5” (from wall 1.5”)
Riser 4”-7”, Tread 11+
Res >10 occ - max riser - 7-3/4”, min tread 10”
36”, 32”, 24”
An accessible route can be 36” min and 32” @ passage for 24” point
If an accessible route is less than 60” wide then need 60”x60” passing point every _____ ft
200
60”, 180 degrees
Need 60” for 180 degree turn for WC
Min accessible residential toilet room
60” wide x 66” long
Tp dispenser how far infront of toilet and outlet ht
7”-9” infront
15”-48” AFF