Solid Radwaste System Flashcards

0
Q

Where does SR/RF receive liquid wastes from?

A

LR, CH, and PC

Also takes solid disposable Radwaste

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

What components make up the SR/RF system?

A
Spent resin tanks
Vendor supplied system CD-600
Filter handling system
Dry active waste processing & storage (DAWPS) facility
Portable resin drying system
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How long does a Radwaste operator have to acknowledge an alarm on the SR/RF system before the control room alarm comes in?

A

5 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the difference between the high activity spent resin tank and the low activity spent resin tank?

A

High activity tank has more shielding and receives resin from CH and PC ion exchangers.
Low activity gets spent resin from the LR system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Describe how resin removal is accomplished from the spent resin tanks.

A

There is a line inside a line which provides sluice water in the outer pipe area through a Johnson strainer to the inner pipe area. This transports resin with an eductor effect as the water/resin exits the pipe.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What type of pump is the resin transfer/dewatering pump and what supplies the seal water to this pump?

A

Progressive cavity pump.

Reactor makeup water supplies seal water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What will cause the resin transfer / dewatering pump to trip?

A

Low suction pressure or electrical protection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What form does the liquid Radwaste take when the CD-600 vendor unit is done with it?

A

It is a white powder or a thick paste called a salt block that sets up in about an hour.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What must be done if the CCTV malfunctions during CD-600 transfer, filling, or flushing?

A

The transfer or flush must be secured until the problem is resolved.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How many resin drying systems are there?

A

One portable unit to be shared by all 3 units

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How is moisture removed from the air that is pumped through the resin bed during the drying process?

A

The entrainment separator tank contains refrigeration coils to condense the moisture.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What must be monitored closely during resin drying operations?

A

Temperature of the waste and waste container has to be monitored due to the possibility of an exoteric reaction while drying the resin.
If it happens, the container has to be flooded with water, so the waste transfer hose has to stay connected until the fill head is removed.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is used to shield and transport radioactive filters?

A

Radioactive filter transfer cask is used to shield and a 5 ton monorail hoist is used to transfer it.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly