SH Chapter 2 - Air Systems Flashcards
1) Which valves will receive a close command when the DITCHING pushbutton is depressed (ARPO)?
- Avionics ventilation inlet & outlet fans
- Ram Air inlet
- Pack flow control valves
- Outflow valve
2) Will the DITCHING pushbutton always close the outflow valve?
No. Only when the pressurization mode is in Auto
3) Can the pilot control the outflow valve?
Yes. When MODE SEL pb in MAN (manual pressurization mode)
4) How many controllers are in the pressurization system?
Two. Identical digital pressurization controllers (CPCs)
5) How do you manually switch controllers?
Switching to MAN for at least 10 seconds, then back to Auto (MODE SEL pb on CABIN PRESS panel)
6) What does an amber FAULT light in the MODE SEL pushbutton indicate?
Both CPCs have failed
7) From what source does the pressurization system obtain landing elevation?
Auto - FMGC 1
Semi Auto - LDG ELEV Knob
8) When the mode selector is out of the AUTO position, how do you set a landing elevation?
Turning the LDG ELEV knob to field elevation and confirming on ECAM panel.
9) What protects the airframe from excessive cabin differential pressure?
Safety valves (two independent valves)
10) How many outflow valve motors are installed?
Three. Two for automatic and one for manual.
11) What happens to the pack flow rate when APU bleed air is in use or during single pack operation?
System provides higher flow rate
12) When should the PACK FLOW selector not be in the normal position?
With less than 115 pax - LO
Hot or humid conditions - HI
Or as directed for smoke ventilation
13) If the engine bleed air in-flight is too low what will occur?
Controller sends a signal to both Engine Interface Units (EIUs) to increase minimum idle and raise bleed pressure
14) What would cause an amber FAULT light to illuminate in the PACK 1 and/ or Pack 2 pushbutton (OOD)?
- Pack outlet overheat
- Compressor outlet overheat
- Pack outflow valve position disagrees with selected position
15) At what cabin differential pressure does the RAM AIR valve open?
Less than 1 diff
16) What causes the Pack Flow Control valve to automatically close?
- Low bleed pressure
- Compressor outlet overheat
- Associated FIRE pub pressed
- DITCHING pb selected ON
- Engine start sequence