Sec - 9 (Inspection) Flashcards

1
Q

Holiday testing of thick-film linings shall be carried out with a ,,,,,,, in accordance with NACE ,,,,,,,

A

high-voltage detector

RP0188.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Holiday testing of thin-film linings should be performed with a ,,,,,

A

low-voltage (67.5 volts) wet sponge detector

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A tank bottom lining with a measured thickness of 15 mils should be tested by……

A

low-voltage (67.5 volts) wet sponge detector

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

All lining inspectors should be ,,,,,,,,,,,????? of coating and lining practices

A

either NACE or SSPC certified, or should have demonstrated a thorough knowledge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly