Sec - 9 (Inspection) Flashcards
1
Q
Holiday testing of thick-film linings shall be carried out with a ,,,,,,, in accordance with NACE ,,,,,,,
A
high-voltage detector
RP0188.
2
Q
Holiday testing of thin-film linings should be performed with a ,,,,,
A
low-voltage (67.5 volts) wet sponge detector
3
Q
A tank bottom lining with a measured thickness of 15 mils should be tested by……
A
low-voltage (67.5 volts) wet sponge detector
4
Q
All lining inspectors should be ,,,,,,,,,,,????? of coating and lining practices
A
either NACE or SSPC certified, or should have demonstrated a thorough knowledge