SCBA Flashcards
The sensor module of the Scott Air-Pak 75 5.5 is outfitted with lights. The lights will flash red alternately when the _____.
Personal Alert Safety System (PASS) pre-alarm is sounding
Each SCBA cylinder is required to be hydrostatically tested every _____ years. Any cylinder with a past-due hydrostatic test must be removed from service.
five
While carrying out an interior attack on a fire, a member’s partner experiences a mechanical malfunction of his/her SCBA. The member’s own SCBA remains in working condition. What shall apply in this situation?
The member must immediately leave the contaminated atmosphere with his/her partner and notify his/her officer.
When a user has an intact and functioning SCBA with a low air supply, the rapid intervention universal air connection (RIC/UAC) may be utilized to trans-fill compressed air from the RIT-Pak cylinder to the cylinder needing air. What is one of the cons of this method?
The user is limited to half of the supply cylinder’s pressure/volume after trans-filling.
Which of the following members is cleaning and disinfecting an SCBA facepiece assembly CORRECTLY?
A member wets an entire facepiece, including all rubber and plastic areas.
The sensor module of the Scott Air-Pak 75 5.5 is outfitted with lights. The lights will flash orange once a second when the _____.
battery is low while on
Scott Pak-Tracker transmitter signals will react differently with different types of building materials. What materials will transmitter signals usually pass through?
Wood
An SCBA cylinder has cuts that have penetrated through the outer layers of plastic and cut the fiber over-wrap threads, though they have not exposed the bare metal beneath. The cylinder has _____ damage and shall be _____.
Level 2; placed out of service
When inspecting the Scott RIT-Pak portable air supply, personnel should ensure that it has been flow-tested within _____ of the current date.
1 year
Since the weight of an SCBA is designed to be carried on the _____, the _____ to avoid causing fatigue.
hips; waist straps must be adjusted prior to the shoulder straps
Assessment of adequate respiratory protection of a downed firefighter is paramount to the rescue effort and may be performed using the acronym ABCS. What does the “S” in ABCS stand for?
Straps
The sensor module of the Scott Air-Pak 75 5.5 is outfitted with lights. The lights will flash orange alternately when the _____.
battery is low while on
Scott Pak-Tracker transmitter signals will react differently with different types of building materials. What material will transmitter signals usually reflect off of?
Concrete
Any SCBA cylinder _____ years and older must be removed from service.
15
Personnel can check the batteries of the manual Scott Pak-Alert alarm by depressing the _____.
reset button (yellow button) once