Metrorail Emergency Service Flashcards
May the emergency stop switch on the kiosk escalator monitoring panel be used to stop escalators?
No, because this emergency stop switch has been disconnected;
the emergency stops are located only on the escalators.
Each yard and service facility is composed of several buildings and areas. Which buildings typically contains a “stinger” 750-volt system that allows power to be supplied to the rail cars to move them in and out of the building?
The service and inspection shop.
What statements about the wayside telephone system is CORRECT?
Conference calls can be made from a wayside telephone by notifying the Operations Control Center (OCC).
When a fire alarm is received from a zone in a station, the automatic public address announcement system (APAAS) activates to provide the station manager with a pre-alert of a fire alarm that needs attention. The station manager will have_____ to react to the alarm.
2 minutes
Five types of sensors are used in the Metrorail fire alarm system. Which type is used in sensitive or critical areas, such as train control rooms and communication rooms?
Ionization detectors.
An alarm is transmitted by flammable vapor and gas detection (FV&G) sensors if ambient vapor levels are exceeded. The system is calibrated so that a warning is transmitted if _____ percent of the lower flammable limit for the product is reached, and an alarm is transmitted if _____ percent of the limit is reached.
20; 40
What statements about the warning strobe and alarm device (WSAD) is CORRECT?
Should one of the WSAD paddles fall off of the third rail or running rail, the warning horn will activate.
When passengers are trapped in an elevator, several procedures should be rechecked or attempted to see if the problem can be corrected without the assistance of the elevator mechanic. What should DCFEMS attempt FIRST in this situation?
Shutting down and restoring the main electrical power in the elevator machine room.
According to the Metrorail Emergency Services Manual, for elevators , to originate a call from the kiosk, personnel should depress the _____.
appropriate elevator car or landing button and then depress the “press-to- talk” button
According to the Metrorail Emergency Services Manual, what is the recommended procedure for removing entrapped passengers from an escalator?
Prying the steps away from the sideboards.
What shall apply when evacuating passengers from a tunnel?
Prior to evacuating passengers into the tunnel, all third rail power must be shut down between the emergency scene and the planned exit locations.
There are three separate types of electrical loads found in the Metrorail system: non-essential, essential and emergency. What is/are considered an emergency load?
Communications equipment.
Tunnel ventilation is achieved by four different modes of operation. In the high temperature mode (above 95 degrees Fahrenheit), _____.
dampers are open and fans are operating in the exhaust setting
The Metrorail Emergency Services Manual includes what tactical considerations for using tunnel fans during evacuations?
If fans are not in operation, shafts may experience the chimney effect.
The types of flammable gases and vapors encountered near the Metrorail right-of- way are gasoline, liquefied petroleum gas (LPG) and natural gas. What gases and vapors are the MOST likely substances to be found?
Gasoline and LPG.