When donning SCBA, fire fighters should check that the cylinder has a minimum of __ % of its rated maximum pressure.
90
The realistic duration of an SCBA air supply is ___ than the rated duration.
Much shorter
What is the primary function of the red purge valve on an SCBA?
Supply air in the event of a regulator malfunction
NFPA standards require an SCBA low air alarm to sound when the cylinder pressure drops to ___ % of capacity.
35%
Pressure readings on an SCBA cylinder gauge and the regulator or remote pressure gauge should not differ by more than __ %.
10%
Which type of breathing apparatus recycles the user’s exhaled air?
Closed Circuit
What is the function of the bell on the SCBA?
Warn a SCBA wearer of low cylinder pressure.
The __ type of SCBA is most commonly used in fire fighting. This type of SCBA vents exhaled air to the outside atmosphere.
open-circuit
Which of the following statements is true:
A) Most SCBA cylinders are made of steel
B) SCBA cylinders are periodically run through hydrostatic testing
C) The minimum quality for air used in SCBAs is Grade A
D) Regulators on SCBA units are only attached to the wrist strap.
B) SCBA air cylinders are periodically run through hydrostatic testing
You are fighting a fire inside a structure with your partner. Your partner’s low air supply alarm begins to sound. What should happen next?
Both you and your partner should immediately exit the structure.
While firefighting inside a structure, debris falls from the attic blocking your exit. Your only way out is through a small opening in the wall. You will not fit through the opening with the SCBA on in it’s normal position. Which of the following statements is true concerning passage through the restricted opening:
A) You can remove your facepiece if needed to squeeze through the opening
B) Loosen the straps of your SCBA and rotate the SCBA unit under the arm along the rib cage as a first step. A last resort is removing the harness assembly and holding the SCBA in front of you
C) You do not need to maintain constant contact with the SCBA unit
D) All of the above
B) Loosen the straps of your SCBA and rotate the SCBA unit under the arm along the rib cage as a first step. A last resort is removing the harness assembly and holding the SCBA in front of you
In the event of an SCBA malfunction, ___.
A) The firefighter should remain calm and exit the hazardous environment immediately with their teammate
B) The firefighter should manually activate the PASS device
C) A “Mayday” message should be announced on the portable radio
D) All of the above
D) All of the above
Terrace Park SCBA cylinders are rated a __ minutes?
45
Methods for donning SCBA include:
Over-the-Head
As the oxygen supply in any given area falls below __ %, unconsciousness can occur.
9%