SCBA Flashcards
SCBA Manufacturer
Honeywell Titan
SCBA Components
■ Backpack and Cylinder
■ First-Stage Regulator
■ Heads-up Display (HUD)
■ Chest Air Pressure Gauge w/ IntelliPASS
■ Second-Stage Regulator
■ Emergency Buddy Breathing System w/ “Y” Block
SCBA Backpack Components
lightweight aluminum backplate with an aluminum hip- plate that hinges
1,000 lb. of pull strength
4 large openings on the backplate specifically designed for carabiner attachment points and can withstand 1,000 lb. of pull force.
Central Power Supply. 4 “C” Alkaline batteries provide power to the front and back PASS, all indicator lights and all electronic audible alarms, HUD, as well as thePathfinder locating system.
SCBA Air Cylinder Composition
- Thin walled aluminum liner
- Smooth internal finish
- Insulating layer
- Carbon Fiber over wrap in
epoxy resin - (FRP) Fiberglass reinforced
plastic - Radius base
- Parallel thread
SCBA max working pressure
4500 PSI.
SCBA air cylinder pressure gauge
graduated in 1000 lb. increments from 0-6000 lbs with the full bottle range (4000-5000 lbs.)
SCBA cylinder sizes
45 min - 65.6 cubic feet of air
60 min. - 87 cubic feet of air
40 liters per m
When to change scba air cylinder
When the cylinder gauge reads less than 4000 lbs.
SCBA air cylinder testing and life span
Hydrostatic Test when new
retested every 5 years.
15-30 year life span.
(tested at 7500 psi)
First stage regulator pressure
115psi
When does the relief valve activate to protect the system?
when intermediate pressure exceeds 200 to 225 psi
At what pressure does the warbling whistle activate
at 1485 to 1665 psi (33-37%)
HUD Light Progression
Full- 4 green lights
¾- 3 Green lights
½- Green Light flashes for 20 seconds then both solid green
1/3- Light flashes red at rate of 500 milliseconds
10%- 1/3 light flashes at rate of 100 milliseconds
PASS alert timing
approximately 20 seconds. The LED lights will alternate flashing green and red. The alarm will increase in volume approximately every 4 seconds until full alert at 30 to 35 seconds. In full alert, the LED lights flash red and the alarm tones alternate between the front and rear mounted speakers.
What is the PASS powered by
4 “C” alkaline batteries in the backpack.
The Emergency Breathing Safety System (EBSS) length and makeup
39 inch intermediate pressure hose and a “Y” block with a male and female quick connect.
SCBA Daily Check Required Equipment
SCBA Harness
45 Minute Bottle
Facepiece
Turnout coat
Voice Amplification System (VAS)
SCBA Daily Check
https://docs.google.com/document/d/1puhlRmG4Q4v4j4bj1_9W-sHpJOAmslvYWEMGNjCCBr8/edit#
How often shall personnel inspect their SCBA
Daily
What form shall be initialed after completion of daily SCBA inspection
Form 20