Safety & Power On Checklist Flashcards

1
Q

Maintenance Status—Checked

What are you checking for?

A
  1. Verify all maintenance items are appropriate and all MEL/CDLs considered cleared.
  2. Circuit breakers are either in (closed) or out (collared) as appropriate.
  3. Check for a valid Air Worthiness and 2-Day check.
  4. Verify all applicable safety items are on board.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What if maintenance is on board the aircraft?

A

Do not operate the aircraft controls and consult the mechanic.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

GPU…OUT

What happens when the GPU pushbutton is out?

A

Isolates the AC GPU from the AC BUS TIE.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

APU GEN…IN

What happens when the APU pushbutton is in?

A
  1. Connects APU generator to the AC BUS TIE provided the power is within limits.
  2. Allows automatic operation of the electrical system.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

BATT 1 & 2…OFF

What happens when the battery switches are off?

A

Batteries 1 & 2 supply power to their respective HOT BATT BUSES

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Name six items on the HOT BATT BUSES

A
  1. Engine fire extinguishers
  2. Fuel shutoff valves
  3. Hydraulic shutoff valves
  4. Engine oil level systems
  5. Refueling panel
  6. Water and waste systems
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

FUEL DC PUMP & AC PUMPS 1 & 2… AUTO

What happens when these switches are in AUTO?

A

Automatically operates the pumps according to the systems logic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

HYDRAULIC SYS 1,2, & 3B ELEC PUMPS … AUTO

What happens when the switch is in AUTO?

A

Allows the electrical pumps to operate automatically according to hydraulic system logic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

BATT 1 …ON

What is the minimum voltage?

A

22.5V

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What if the batteries are not at 22.5V

A

GPU can power the airplane. Chart in Chapter 6 of the SOP should be referenced to determine how long is necessary to recharge the batteries.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

BATT 2 … AUTO

What is the AUTO function of BATT 2?

A

Allow the #2 battery to power APU start bus during APU start

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Is BATT 1 involved in the APU start?

A

Yes, BATT 1 powers the APU FADEC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What indications are you looking for when you perform the Fire Panel Test?

A
  • That there is no “FAIL “fire detection/extinguishing system messages on the EICAS.
  • The APU fire extinguishing button and the upper half of the APU emergency stop button illuminates.
  • The FIRE icons are displayed on the ITT gauges.
  • The fire bell and master warning sound.
  • The fire handles illuminate.
  • The cargo fire buttons illuminate.
  • 5 Red messages on the EICAS.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What does the AVAIL light on the GPU switch indicate

A

The AC GPU is connected and the voltage/amperage/frequency are within limits

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the APU starter duty limitation?

A

1st and 2nd attempt 60 seconds ON;60 seconds OFF.

3rd cycle 60 seconds ON; 5 minutes OFF.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the MAX altitude for APU start?

A

30,000 ft

17
Q

What is the max altitude for operation of the APU electrical

A

33,000 ft

18
Q

What is the max altitude for operation of the APU bleed?

A

15,000 ft

19
Q

What is the max altitude for an APU assisted engine start?

A

21,000 ft

20
Q

How is the APU monitored and controlled?

A

FADEC

21
Q

What happens when you rotate the APU master switch to on?

A

Powers the FADEC and opens the APU fuel shutoff valve

22
Q

What happens when you rotate the APU selector knob to off?

A

Initiates the normal shutdown sequence, a 1 minute cool down period begins, the APU pneumatic is removed immediately and electrical power is removed after the 1-minute cool down period.

23
Q

What happens when the APU EMERGENCY STOP button is pushed?

A

The APU fuel shutoff valve closes and the APU will shut down with no cooling period.

24
Q

What emergency equipment do you check for in the flight deck?

A
  • 1 PBE
  • 1 Halon fire extinguisher
  • 1 Crash axe
  • 2 flash lights
  • 2 escape ropes
  • 3 life vests