What are the flow rates for a running Containment Spray pump?
3900 gpm
What are the flow rates for a running LPSI pump?
4250 gpm
What are the flow rates for a running HPSI pump?
850 gpm
What are the recirc limits for the Containment spray pumps?
150 gpm for one hour, 2100 gpm continous
What are the recirc limits for the LPSI pumps?
100 gpm for one hour, 2400 gpm continous
What are the recirc limits for the HPSI pumps?
85 gpm for one hour, 225 gpm continous
What is the Containment spray system expected to reduce containment from max design pressure to?
Reduce pressure from peak value to 1/2 peak in 24 hours
What is used to fill the SIT’s?
The ‘B’ HPSI Pump
What does a SIT need to be considered operable?
MOV full open with power removed, with sufficient volume, boron concentration, and N2.
What is the limit to heating up the SDC loop? What is the limiting component?
19 degrees F per min. The SDC HX.
What is the flow limitation for RWLIS to be accurate if the same train of SDC is being used?
5000 gpm. Above 5000 gpm you should use the other train of RWLIS indication as it will be more accurate.
What is the temperature limit above which SDC header venting shouldn’t occur?
200 degrees F
How are the SDC containment isolation valves interlocked?
If pressurizer pressure is greater then 385 psia they will not open
What is the SDC low flow alarm set-point for one pump operation?
3615 gpm
What is the SDC low flow alarm set-point for two pump operation?
7400 gpm
If a LPSI or CS pump is shutdown for greater then one hour, how many consecutive starts may be attempted?
Two
If a CS or LPSI pump is shutdown for less then one hour, how many consecutive starts may be attempted?
One
What are the limits that are in place for placing a CS pump into service for SDC?
RCS temp- 200 degrees F
RCS press- 250 psia
What is the Safety Injection system’s design basis?
-Peak Cladding temp
What is SDC design basis?
- Cool the RCS to 125 degrees F in 27.5 hours
- Limit core HUR and CDR to 75 degrees F/hr
- Capable of 1 year operation following LOCA
- One train maintain RCS temp
Containment spray system design basis?
- Prevent exceeding containment design press and temp (60 psig and 300 degrees F)
- Maintain containment press and temp at acceptable level during recirc ops.
- Reduce containment pressure from peak value to 1/2 peak value in less than 24 hours.
- Provide 100 percent of the required heat removal capability an partially remove iodine from the containment atmosphere.
What is the LPSI pumps shutoff head?
150 psia
CS pump shutoff head?
150 psia
What is the design pump flow in the CS and LPSI pumps?
5000 gpm
Around how much volume does a SIT contain?
14,000 gallons