SAAB 340B Pneomatics Flashcards
What compressor stage is the LP air taken from?
5th
What compressor stage is HP air taken from?
6th
What compressor stage does P3 air come from?
6th
What compressor stage does P2.5 air come from?
5th
How is the HP valve controlled?
Electrically
How is the HP valve operated?
Pneumatically
What are the reasons the HP valve would automatically close?
Reason 1
Bleed air over temp (288 deg C)
What are the reasons the HP valve would automatically close?
Reason 2
Bleed air over pressure (76 PSI)
What are the reasons the HP valve would automatically close?
Reason 3
Fire handle is pulled
What are the reasons the HP valve would automatically close?
Reason 4
Engine is shut down
What are the reasons the HP valve would automatically close?
Reason 5
Main DC bus power is lost
What are the reasons the LP valve would automatically close?
Reason 6
Bleed air over temp (288 C)
What are the reasons the LP valve would automatically close?
Reason 7
Bleed air over pressure downstream of valve (43 PSI)
What are the reasons the LP valve would automatically close?
Reason 8
Fire handle is pulled - Air conditioning pack over temps (225 C)
What are the reasons the LP valve would automatically close?
Reason 9
Fire handle is pulled - Air conditioning duct over temps (82 C)
What does a BLD CLOSED light indicate?
Bleed valve is closed
What does a BLD FAULT light indicate?
1
Bleed air temperature excessive (>288 C)
What does a BLD FAULT light indicate?
2
Regulated pressure excessive (>43 PSI) - Valve fails to close when signaled too close
What does a HP HIGH light indicate?
Valve fails to close when signaled too close
How is HP air cooled?
Ram air heat exchanger, Precooler