What are the purposes of the 6 quatrefoil tube support plates?
Helps provide lateral support and minimizes vibration
What is my cooling medium for my sample? Hot side/cold side/MW?
Primary - CCW cools samples by 130F
Secondary- SW cools samples to 77F
MW-A closed loop temperature control unit provides chilled water.
PASS provides the means to perform what?
- Remote collection of RCS, RHR, and CV atmosphere
- Dilution of the samples for withdrawal.
- Collection of undiluted grab samples.
(The information obtained from the analysis of the samples will enhance efforts in assessing and controlling the course of an accident
What is Hydrazine used for?
Is added for oxygen control during start-up. In addition, hydrogen gas is placed on the VCT
Mispositioned Component definition
Any Active Positionable Component placed in or
left out of the required position for existing plant conditions when the
component’s required position is tracked by one or more status control tools.
RCV-609 is special how?
Gagged open to prevent over pressurization of CCW system
CC-707 does what?
serves as a secondary relief to back up RCV-609
HCV-1459 interlocks and setpoints?
-Interlocked with QCV-10426
-only works in auto if both MFP are running
-Opens when MFP suction pressure drops to 300psig
-Opens when MFP suction pressure drops to 350psig and both HDPs have tripped
-auto closes when MFP suction pressure increases to >400psig
Continuous attendance definition (FP-all-1520)
An individual assigned or designated to provide an uninterrupted presence, visual observation and physical control of a transient combustible at all times.
EH pump power supplies?
A- MCC-4
B- MCC-3
What pressure does the standby EH pump start at?
1350psig if in auto
High lvl and low lvl temperature alarms for EH?
140F hi
80F low
(must be at least 70 to start a pump)
(Electric heaters maintain temp between 100-110F, energize and deenergize at these temps)
EH FLUID RESERV LO LEVEL? does what?
7.625” from bottom of tank.
Locks out the non-running pump. Cannot manually start standby EH pump
200g tank, normally 140g
What temperature in the EDG room causes them to be inop?
40F
What panel is 115SUT relays on?
Panel 11