AOCT Oct. 24 Flashcards

1
Q

SGBD process variable shows what?

A

The tank level

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

SGBD control variable shows what?

A

The position of the FCV-4213’s, which controls the level in the flash tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

AVR system upgrade, where it is located for alarm response

A

South of RCA (east) access. Do not need password for alarm review, MR key required for enclosure access
ECT (Excitation Control Terminal)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Fall protection. Distance required for fall protection for a unprotected edge. (SFP, Cavivity)

A

6 feet from the edge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

QCV-10426 (Secondary Bypass Valve) opens on?

A
  • Loss of Air
  • Loss of Power
  • High inlet temp (140F)
  • High System DP (65psid)
  • HCV-1459 opening (interlocked with each other)
  • Has a 10 min TD for closing if any of the above clear
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Will all the transformers be worked on this outage?

A

YES THEY WILL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Should you open a coolant pressure cap while the engine is running?

A

NO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Zone 19 is what?

A

Unit 2 cable spread room

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Zone 20 is?

A

E1/E2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the fire suppresion in zones 19/20?

A

Halon

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the time delay for the suppresion in zone 19/20

A

17 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How many bottles of halon are dumped into zone 19?

A

4 cylinders

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How many bottles of halon are dumped into zone 20?

A

10 bottles

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the power supply for QCV-10425 (Primary bypass valve)

A

MCC-13

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What does the primary bypass valve control?

A

Unprocessed Condesate
It does not force flow into the CP vessels, but does close 20% for each vessel in service

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is a fail safe item in FME concerns?

A

A condition that ensures an item cannot:
Enter a SSC due to size
Be easily broken apart
Sink in a body water

17
Q

IVSW is rest where?

A

Unit 2 Cable spread room, can only be reset after the SI signal that caused a Phase A is reset.

18
Q

CV design pressure and temperature

A

42psig
264F

19
Q

What provides pressure in IVSW tank?

A

Nitrogen header (55psig)
Back up is N2 bottles