SGBD process variable shows what?
The tank level
SGBD control variable shows what?
The position of the FCV-4213’s, which controls the level in the flash tank
AVR system upgrade, where it is located for alarm response
South of RCA (east) access. Do not need password for alarm review, MR key required for enclosure access
ECT (Excitation Control Terminal)
Fall protection. Distance required for fall protection for a unprotected edge. (SFP, Cavivity)
6 feet from the edge
QCV-10426 (Secondary Bypass Valve) opens on?
- Loss of Air
- Loss of Power
- High inlet temp (140F)
- High System DP (65psid)
- HCV-1459 opening (interlocked with each other)
- Has a 10 min TD for closing if any of the above clear
Will all the transformers be worked on this outage?
YES THEY WILL
Should you open a coolant pressure cap while the engine is running?
NO
Zone 19 is what?
Unit 2 cable spread room
Zone 20 is?
E1/E2
What is the fire suppresion in zones 19/20?
Halon
What is the time delay for the suppresion in zone 19/20
17 seconds
How many bottles of halon are dumped into zone 19?
4 cylinders
How many bottles of halon are dumped into zone 20?
10 bottles
What is the power supply for QCV-10425 (Primary bypass valve)
MCC-13
What does the primary bypass valve control?
Unprocessed Condesate
It does not force flow into the CP vessels, but does close 20% for each vessel in service