Residential Installations and codes (110104h) Flashcards
The safety of the workers and job sites is governed by which code?
OH & S
The installation of gas appliances and piping is governed by which code?
B149.1-05 CAN/CSA
Natural gas and propane installation code
The part of the job where the pentrations to the exterior are installed is the?
Rough in stage
The part of the job where the furnace is placed in a permanent position is the?
Ductwork stage
Whose responsibility is it to ensure the job is done properly and to the applicable code?
The installer
The clearance between an exhaust hood and regulator vent on natural gas or propane line coming into a building is?
3 feet or 1 meter 39 inches in real job site
Hoods to the exterior should be minimum how far off ground?
18 inches
What size is dryer vent?
4 inches
What size is range hood?
6 inch
What size of duct hanger is used on return air duct?
10 inch
What size of duct hanger is used on hot air duct?
11 inches
What is the easiest way to open drive cleats ?
With a screwdriver
What does hrv stand for?
Heat recovery ventilation
What does ABC stand for?
Alberta building code
What does the ABC ( Alberta building code) list?
A list of technical requirements for buildings constructed in alberta.
What is the agency that tests furnaces?
CSA or
Underwriters Laboratories or
Underwriters Laboratories of Canada
What does the heat loss calculation determine?
Size of furnace used
What are 3 different types of installations for an hrv unit?
No separate ductwork
Separate intake ductwork
Stand alone system
What does SMACNA mean?
Sheet Metal and Air conditioning Contractors National Association
In the sheet metal trade the governing codes that are to be followed would fall under the?
National or Provincial codes
Once the house is framed what should the sheet metal worker do?
Rough in
Once the house has concrete what can the sheet metal worker do?
Basement ductwork