Cold Hung-up or No Light-Off or Overtemperature On Start
Fuel Lever - OFF - P
Starter Switch - Hold L/R (observe starter limits) Normal max 40 seconds, 25 seconds for no light - P
Shutdown Checklist - Complete as required - P/CP/FE
Low Oil Pressure During Start
Fuel Lever - OFF - P
Shutdown Checklist - Complete as required - P/CP/FE
Generator Light Fails to Come On After Start or On Shutdown
Affected Generator - Verify OFF - P
If generator light remains OFF continue as follows:
EXTERNAL/BATTERY - OFF - P
Fuel Lever - OFF - P
Shutdown Checklist - Complete as required - P/CP/FE
Ground Evacuation / Engine Fire On the Ground
Parking Brake - Set - P
Power Levers (Both) - IDLE - P
Prop Levers (Both) - FEATHER - P/CP
Fuel Levers (Both) - OFF - P/CP
Fuel Emergency Shutoff - OFF (Affected Engine if Required) - P/CP
Fire Pull - PULL (Affected Engine if Required) - P/CP
Boost Pumps - OFF (Both Engines) - P/CP
Notify Crew - Intercom “EVACUATE, EXITS (L/R) SIDE” As Briefed - P
Evacuate Passengers - - CP/FE
DC Master - OFF (consider ON at night) - P
Standard Abort
Power Levers - IDLE. REVERSE as required - PF/PM
Brakes - as required - PF
Engine Failure - Below Vmc
Power Levers - Reduce to Maintain Control - PF
Land - Straight ahead (only minor corrections to avoid obstacles) - PF
Engine Failure - Above Vmc
Power/Prop Levers (unaffected engine) - as required - PF/PM
Flaps - as required - PF/PM
Propeller (affected engine) - confirm feathered (manually feather if required) - PM/FE
Climb to safe altitude - as required - PF
Power Lever (affected engine) - IDLE - PM/FE
Propeller Lever (affected engine) - FEATHER - PM/FE
Engine Fire Airborne
Affected Engine
Power Lever - IDLE - PM/FE
Prop Lever - FEATHER - PM/FE
Fuel Lever - OFF - PM/FE
Fuel Emergency Shutoff - OFF - PM/FE
Fire Pull - PULL - PM/FE
Boost Pump - OFF - PM/FE
Steady Beta Range Light
Power lever - Reduce to prevent overtorque - PF/PM
Intermittent Beta Range Light
Propeller levers (both) - minimum governing - PF/PM
Power levers - maintain equal torque - PF/PM
Pitch Trim Runaway
Aircraft - Manually control - PF
Trim Interrupt / Autopilot Disconnect - Depress - PF/PM
Total Electrical Failure
But tie - Open - PF/PM
L/R Generator - OFF - PF/PM
Generator - Reset individually (two attempts) - PF/PM
Fuselage / Electrical Fire
Crew / Passengers - Notify - PF/FE
Oxygen Mask / Regulators (if available, as time permits) - Don / 100% Oxygen - P/CP/FE