Radiology Flashcards

1
Q

What is the max dosage per year for radiation for staff?

A

5.0 Rem/yr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the greatest hazard for staff?

A

Scattered x-radiation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Where does scatter radiation come from?

A

The patient

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What view is most hazardous for staff?

A

LAO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Where are the two film badges to be placed?

A

One on the collar outside the apron, one on the belt inside the lead apron

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the lowest frame rate?

A

7.5 FPS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the correlation between X-ray exposure and frame rate?

A

As frame rate increase the exposure increases

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

This view helps differentiating the atria from ventricles

A

RAO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

This view helps locating the CS os

A

RAO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

View that is great to see the coronary sinus

A

LAO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

In this view you can see enface through the mitral valve and tricuspid

A

LAO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

This view helps differentiate the left and right side of the heart

A

LAO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

This view assists in placing the CS and atrial mapping catheters

A

LAO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Image intensifier is 45-60 degrees

A

LAO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Imagine intensifier is 30 degrees

A

RAO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What view is best to see the entire anterior of the RV?

A

RAO

17
Q

Which fluoroscopic view is most utilized to visualize the LAA for a closure procedure?

A

RAO caudal

18
Q

What is the measurement for the absorbed x-ray dose?

A

RAD

19
Q

Best x ray view to visualize the CS veins for a LV lead placement?

A

LAO

20
Q

What X ray view is best for a venogram prior to a PPM?

A

RAO

21
Q

What X ray view is best for positioning the CS catheter?

A

LAO

22
Q

What X ray view is best to determine if the catheter is in the RVOT?

A

RAO