Why are some water-cooled condensers cleaned with brushes and others with chemicals?

a) chemicals are only used on outdoor condensers, indoor condensers are cleaned with brushes
b) some water-cooled condensers will accumulate scale while others do not
c) all water-cooled condensers are hermetically sealed and cannot be cleaned with brushes
d) some condenser tubes are not straight and will not allow brushes to pass through them

A

d) some condenser tubes are not straight and will not allow brushes to pass through them

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The three materials of which air-cooled condensers are normally made are _______

a) brass, aluminum, and cast iron
b) brass, copper, and steel
c) copper , aluminum, and steel
d) copper, cast iron, and brass

A

C) copper, aluminum, and steel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

One of the differences between air-cooled and water-cooled condensers is the _______________

A) compressor discharge line temperature

B) Type of compressor used

C) Refrigerant condensing temp

D) Type of refrigerant used

A

Refrigerant condensing temperature

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When is the most heat removed from the refrigerant in the condensing process?

A) when the liquid refrigerant leaves the condenser

B) when the vapour enters the receiver

C) During the change in state from a liquid to a vapour

D) During the change in state from a vapour to a liquid

A

D) during the change in state from a vapour to a liquid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

After heat is absorbed into the water in a water-cooled condenser, the water can be ____________

a) treated with chemicals and piped to a chiller
b) wasted down the drain or sent to a cooling tower
c) filtered and used for drinking water
d) filtered and then treated with chemicals before being reused domestically

A

b) wasted down the drain or sent to a cooling tower

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A water-cooling tower capacity is governed by what aspect of the ambient air temp?

a) dry-bulb temperature
b) wet-bulb temperature
c) altitude
d) enthalpy of the air

A

b) wet-bulb temperature

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When a standard-efficiency air-cooled condenser is used, the condensing refrigerant will normally be _________ above the ambient air temperature

A) 15F

B) 60F

C) 45F

D) 30F

A

30F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Fan cycling, air shutters or dampers, condenser flooding, and VFD condenser fan motors are all methods for controlling __________

a) evaporator capacity
b) electrical efficiency
c) suction pressure
d) head pressure

A

d) head pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

An outdoor air-cooled condenser that has a vertical coil can be affected by the ___________

A) refrigerant oil type

B) prevailing winds

C) indoor ambient temperature

D) municipal water temperature

A

B) Prevailing winds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Air-cooled condensers are ______________

a) being phased out due to their inefficiencies
b) much more efficient than water-cooled cond.
c) less efficient than water-cooled condensers
d) the most efficient condensers on the market

A

c) less efficient than water-cooled condensers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The type of condenser that has straight copper tubes that are fastened into an end sheet within a steel shell that is typically used in large installations is the _____________ condenser

a) shell-and-tube
b) shell-and-coil
c) tube-within-a-tube
d) air-cooled

A

a) shell-and-tube

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

On a system that uses a floating head pressure, ____________________

a) the condenser must be located outdoors
b) more system heat is available for heat reclaim coils
c) the amount of heat discharged from the condenser is extremely high
d) less system heat is available for heat reclaim coils

A

d) less system heat is available for heat reclaim coils

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When the hot discharge gas enters the compressor, it is first _______________

a) condensed
b) de-superheated
c) vaporized
d) sub-cooled

A

De-superheated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

A 2-ton wastewater system that operates approximately 16hours per day would use about __________gallons of water per day

a) 5760
b) 2880
c) 7880
d) 11,520

A

2880?

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

A 10-ton water-cooled system that recirculates water through a cooling tower averages 16 hours of run time per day. The amount of water that would be circulated in a day would be about __________ gallons

A

3 x 10 x 16 x 60 = 28,800

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

In a water-cooled system that recirculates water through a cooling tower, the refrigerant in the condenser typically condenses at _________ above the leaving water temperature

a) 20F
b) 25F
c) 10F
d) 30F

A

10F

17
Q

A system that uses heat from the compressor discharge line to provide heated air or water to a conditioned space is called a _____________ system

a) water recirculating
b) energy recovery ventilator
c) latent boost
d) heat reclaim

A

d) heat reclaim

18
Q

A typical water-cooling tower can cool the water to within _____ of the ambient air wet-bulb temp

a) 3 to 4F
b) 5 to 6F
c) 9 to 10F
d) 7 to 8F

A

d) 7 to 8F

19
Q

Due to the seasonal temp variations of municipal water, a wastewater system ______________

a) has a constant water flow rate to maintain adequate head pressure
b) should have an auxiliary air-cooled condenser to stabilize system pressures
c) has no definite refrigerant-to-water temp relationship
d) has a defined refrigerant-to-water temp relationship

A

c) has no definite refrigerant-to-water temperature relationship

20
Q

The component that varies the flow of water through a water-cooled condenser to maintain a stable head pressure is called a _________

a) ORI head pressure valve
b) low-ambient control valve
c) ORD head pressure control
d) water-regulating valve

A

d) water regulating valve

21
Q

Briefly describe what is meant by floating head pressure and tell why it is used in refrigeration and AC systems?

A

It’s the term for attaining the lowest possible condensing pressure. These systems allow the condensing press to follow ambient temperature as the seasons swing from summer to winter

22
Q

How to flush impurities from a water-regulating valve that is on a water-cooled condenser?

A

By using a brush or chemicals

23
Q

Name two problems a refrigeration system may have if the condensing unit is exposed to a low ambient condition when not equipped with a low-ambient head pressure control valve;

A
  1. expansion device could starve evaporator

2. less heat to be available for the heat reclaim coils to heat buildings

24
Q

briefly explain what is meant by condenser splitting and explain its main advantage:

A

Dividing condenser into two equal circuits to avoid flooding. Reduces extra ref charge needed for condenser flooding

25
Q

A device that passes outside air over water to remove the system heat is a _________

a) shell-and-coil condensers
b) water tower
c) cooling tower
d) shell-and-tube-condenser

A

c) cooling tower

26
Q

Natural draft, forced draft, and evaporative are all types of;

a) cooling towers
b) package refrigeration systems
c) wastewater systems
d) refrigerant phases

A

a) cooling towers

27
Q

Condensing temperatures can be reduced by reducing the condenser surface area

True or False

A

False

28
Q

For every 1 degree rise in suction gas temperature returning to the compressor, there will be a ________ degree rise in the compressor’s discharge temperature

a) 10
b) 1
c) 30
d) 5

A

b) 1

29
Q

A ____________ can be piped into the high-side of the system to cycle the condenser fan on and off during a low ambient condition

a) thermostat
b) pressure control
c) head pressure regulator
d) thermostatic expansion valve

A

b) pressure control

30
Q

On a system that uses condenser flooding to control head pressure during low ambient conditions, the receiver should be sized so that it is

a) 80% full when it contains the entire system charge
b) 20% full when the system is operating during a low ambient condition
c) 50% full at all times, during all conditions
d) 100% full when it contains the entire system charge

A

a) 80% full when it contains the entire system charge

31
Q

Any refrigerant receiver should be able to hold all of the systems charge and still have a 25% vapour head for safety

a) true
b) false

A

b) false

32
Q

Condenser flooding is accomplished by _____________ in both mold and cold weather to keep the head pressure constant

a) having enough refrigerant in the system to raise the suction pressure
b) having enough refrigerant in the system to flood the evaporator
c) having enough refrigerant in the system to flood the condenser
d) applying heat to the compressor crankcase

A

c) having enough refrigerant in the system to flood the condenser

33
Q

Low ambient controls are used on ___________ to maintain head pressure during low ambient conditions

a) air-cooled condensers
b) waste water systems
c) water-cooled condensers
d) cooling towers

A

a) air-cooled condensers

34
Q

_______________ systems use water once, it is then piped to a drain

a) air-cooled condenser
b) package
c) recirculating water
d) wastewater

A

d) wastewater