Metering Device Pretest Quiz Flashcards

1
Q

The low side float is always used with;

a) dry system
b) flooded
c) both
d) neither a or b

A

b) flooded

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The disadvantage of a low side float are;

a) large in size
b) needle valve tends to stick
b) oil binding
d) all of the above

A

d) all of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The high side of a float allows liquid refrigerant to enter the evaporator:

a) on a lowering liquid level in the float chamber
b) on a rise of liquid level in the float chamber
c) liquid level is not a factor
d) when the oil level drops

A

b) on a rise of liquid level in the float chamber

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The high side float is used in a critically charged system;

True or False

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Capillary tubes are generally used with:

a) domestic refrigeration
b) a temperature control
c) hermetic compressors
d) all of the above

A

d) all of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The capillary tube allows the high and low sides of the system to equalize on the off cycle:

True or False

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The AXV is used with:

a) temperature control
b) pressure control
c) flooded evaporator
d) water cooled condenser only

A

a) temperature control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The AXV has difficulty in handling load variations:

True or False

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The main pressures affecting the AXV are:

a) spring pressure, evaporator pressure
b) evaporator pressure, ambient pressure
c) condenser pressure, spring pressure
d) spring pressure, fall pressure

A

a)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The TXV is operated by three pressures. What are they?

a) evaporator, spring, suction pressure
b) evaporator, bulb, condenser pressure
c) evaporator, spring, political pressure
d) evaporator, spring, bulb pressure

A

d) evaporator, spring, bulb pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The thermostatic expansion valve controls;

a) evaporator temperature
b) evaporator pressure
c) latent heat
d) superheat

A

d) superheat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The sensing bulb of the TXV is located;

a) at the inlet of the evaporator
b) at the outlet of the evaporator
c) at the inlet of the condenser
d) at the outlet of the condenser

A

b) at the outlet of the evaporator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

On a multiple evaporator system what type of metering device is normally used?

a) hand expansion valve
b) automatic expansion valve
c) thermostatic expansion valve
d) any of the above

A

c) thermostatic expansion valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where are metering devices located?

a) at the outlet of evaporator
b) at the inlet of the compressor
c) at the middle of the system
d) at the inlet of the evaporator

A

d) at the inlet of the evaporator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The ________ float is not normally used with a receiver.

a) high side
b) low side
c) make up
d) ice cream

Why is it not normally used with a receiver?

A

a) high side

Because it is critically charged

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

To increase the capacity of a capillary tube you can _________

a) straighten it out
b) coil it up
c) put more in the evaporator
d) decrease the length

A

d) decrease the length

17
Q

Which metering device is generally used to handle varying load charges?

a) AXV
b) Hand Valve
c) TXV
d) Any metering device

A

TXV

18
Q

The low side float is controlled by

a) the rate of condensation
b) rate of evaporation
c) the evaporator temperature
d) the evaporator pressure

A

b) the rate of evaporation

19
Q

The AXV controls;

a) condenser temperature
b) evaporator superheat
c) the rate of refrigerant condensation
d) the evaporator pressure

A

d) evaporator pressure

20
Q

The metering device is designed to;

a) keep the evaporator as cold as possible
b) to control evaporator superheat
c) control the flow of refrigerant
d) to keep a constant evaporator pressure

A

c) control the flow of refrigerant