Condenser In Class Quiz 1 Flashcards

1
Q

Where are the location of evaporative condenser water eliminators

a) they are between fans and dampers
b) they are between spray nozzles and fills
c) they are between fans and fills
d) they are between fans and spray nozzles

A

d) they are between fans and spray nozzles

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the minimum hole sizes of protective screen of induced - draft towers

a) 1/4”
b) 3/8”
c) 1/2”
d) 5/8”

A

c) 1/2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What pattern are the fill material of cooling towers in now days usually made into?

a) round
b) honeycomb
c) wave shape
d) diamond

A

b) honeycomb

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What tools should be used to flush a water regulating valve

a) 2 command end screwdrivers
b) a rolling head pry bar
c) a ref service wrench and gauge

A

a) two command end screwdrivers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Which of the following numbers is closest to the weight of water per day a water cooled condenser uses if it is using city water and the systems refrigeration capacity is 5 tons and runtime is 20h/day

a) 36,000
b) 30,000
c) 18,0000
d) 75,000

A

1.5 x 5ton x 20 x 60 = 9,000 x 8.33 = 75,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How much does two us gallons of water weigh?

a) 10lb
b) 20lb
c) 8.33lb
d) 16.66lb

A

d)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

how much is a standard condenser ton?

a) 12,009 BTUH
b) 15,000 BTUH
c) 260 BTUH

A

b)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

what is the temp difference of water in and water out of a water cooled condenser for design purposes when a cooling tower is used?

a) 10F
b) 20F
c) 15F

A

b) 20F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Where is the better location to add water treatment chemicals when automatically chemical feeding water treatment system is used?

a) water pump discharge line
b) water pump return line
c) cooling tower makeup water line
d) cooling tower drain line

A

a) water pump discharge line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What condensers are the co-axial condensers refer to?

a) fin and tube
b) bare tube
c) tube within a tube
d) shell and tube

A

c) tube within a tube

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

what protection gear is recommended when attaching or removing gauges?

a) goggles
b) goggles and gloves
c) safety glasses
d) safety glasses and gloves

A

b) goggles and gloves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How much condenser water is required for a five ton air conditioning system using cooling tower water (US Gallons)

A

5ton x 3gpm = 15GPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

For most standard-efficiency air-cooled condensers have condensers, the refrigerant inside the coils will normally condense at a 30F higher temp than the air passing over it

a) true
b) false

A

true

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Cooling towers can be located inside buildings

True or False

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Ref will normally
condenser at the temp about 10F higher than the entering water temp

True or False

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

While water going into a water cooled condenser is warmer in summer time than in winter time, the water leaving the condenser in the summer would most likely be colder in the winter time

true or false

A

true

17
Q

Tube within a tube condensers are not cleanable

true or false

A

false