Quiz 6 - Commercial Wiring - Unit 9 Flashcards

1
Q

Keeping a refrigerator door open will help cool the surrounding area.

A

True
False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Mechanical refrigeration relies primarily on the process of evaporation.

A

True
False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Cooling the skin is created by,

A

Body heat converting energy from gasoline

Body heat converting energy to alcohol

Body heat being transferred away from the body

All of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The refrigerant cycle requires the following components

A

Expansion valve, compressor, evaporator, condenser

Condensation, evaporation, heat transfer

Refrigerant preservation, evaporation valve, body heat

All of the above

Both A and B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The function of an evaporator is,

A

To add heat and condensation

To evaporate the heat

To remove heat from the interior of a building or space

Both B and C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The compressor serves as a pump to push the expanded refrigerant gas to the evaporator.

A

True
False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The function of the condenser is to discharge the heat extracted by the evaporator and the heat of the compression.

A

True
False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Figure 9-8 is showing,

A

A hermetic compressor which consists of a motor-driven pump completely sealed in a liquid-tight steel casing

A hermetic compressor which consists of a motor-compressor completely sealed in a gas-tight steel casing

A hermetic compressor which consists of a motor-condenser completely sealed in a gas-tight weatherproof casing

All of the above

Both B and C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

CFC’s aren’t harmful to the atmosphere.

A

True
False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Circuit breakers are permitted if a nameplate specifies fuses because they’re both overcurrent devices.

A

True
False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The rated load current,

A

Is governed under 28-010

Is at minimum equal to 64.1% of the MCC (maximum continuous current)

Is equal to 64.1% of the RLA

Both A and C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A common disconnecting means for a starting winding is

A

A contact-relay assembly

A horsepower rated fusible disconnect

A centrifugal switch

All of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

A locked rotor current,

A

Is equal to the full load current

Is approximately six times the FLC

Can be found in Tables 44 or 45

All of the above

Both B and C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The minimum circuit ampacity,

A

Can be obtained by multiplying the RLA by six

Is the rated load current multiplied by a hundred and twenty five percent

Is 125% of the MCA

All of the above

Both A and B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

According to 28-708(1), the maximum overcurrent protective device (MOP),

A

Is the LRC times 1.5

Must not be less than fifty percent of the LRC

Must not be greater than fifty percent of the LRC

All of the above

Both A and C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

According to 2-024, electrical equipment being approved depends on the rating of equipment.

A

True
False

17
Q

According to 28-710, maximum overload protection must be greater than 140% of the RLC.

A

True
False

18
Q

Disconnect switches are

A

Horsepower rated

Rated for low voltage

Rated for ambient temperatures above 30 degrees Celsius

All of the above

19
Q

According to 28-714(1a), disconnects for hermetic motor compressors must not be rated less than 115% of the RLA.

A

True
False

20
Q

A refrigeration disconnecting means shall be capable of safely disconnecting the full locked rotor current according to which rule?

A

28-604(5)

28-714(1b)

28-714(2b)

All of the above

21
Q

The larger value of either the FLA or the LRA will determine the size of disconnect switch installed.

A

True
False

22
Q

According to 28-604(5,6), a disconnecting means must be accessible, within sight, and not more than 3 meters from the air conditioning or refrigeration equipment.

A

True
False

23
Q

Rule 28-708(1) allows a fifty percent size limit on overcurrent protection to be increased to sixty five percent is the equipment cannot start.

A

True
False

24
Q

Rule 28-302 allows for an integral thermal protector to interrupt current flow to a motor compressor.

A

True
False

25
Q

The electricians job is to make sure that equipment is fed by the proper size conductors, with the proper size and type of branch-circuit overcurrent protection, and the proper horsepower rated disconnecting means.

A

True
False