- According to the 2007 Seagrave Apparatus Logbook, What is the cab tilt height?
:. 176 inches (14 ft. 7 in.)
According to the 2007 Seagrave Apparatus Logbook, What is the normal oil pressure at idle ?
37 psi
According to the 2013 KME Apparatus Logbook, what is the capacity of the Diesel Exhaust Fluid (DEF) tank ?
5 gallons
According to the 2013 KME Logbook, The “dead man” safety feature of the Reverse Control System requires the Spotter to continue holding the button down throughout the entire backing process in order to continue giving a “Back Up” signal. If the Spotter accidentally releases the button or loses control of the TRANSMITTER, a “STOP!” signal will instantly be given to the Driver by flashing red light for how many seconds?
3 sec
According to the 2007 Seagrave Apparatus Logbook, how often must the fire pump be lubed ?
every 100 hours
According to the 2007 Seagrave Apparatus logbook, what is the voltmeter reading of the electrical system if the state of charge is 50% ?
12.18 volts
According to the 2013 KME Apparatus Logbook, regarding the World Transmission Operation, the ECU did not complete initialization when all segments of the digital display are illuminated for longer than how long?
12 sec
According to the 2005 Pierce Apparatus Logbook, what is the oil pressure at the rated speed?
30-45 psi
According to the 2005 Pierce Apparatus Logbook, when starting the apparatus, an inspection should be made to determine the cause of an engine that does not start after how many attempts ?
4
According to the 2003 Seagrave Apparatus Logbook, when performing a F-377 Bi-Monthly Inspection, check the steering box and steering linkage by positioning the front wheels straight ahead (wheels on ground). Have an assistant move the steering wheel back and forth using short rapid movements, how far ?
4-6 inches
According to the 2007 Seagrave Apparatus Logbook, what is the operating temperature of the coolant ?
189-208 degrees F
According to the 2010 KME Apparatus Logbook, the apparatus has a special receptacle for connecting to to electrical jumper cables. Where is the special receptacle located ?
Underneath on the left side of the apparatrus, just adjacent to the battery box
According to Book 8, Driver’s Training Manual, safety belts are ______ percent effective in preventing fatalities and injuries ?
50-65%
According to DB 11-12, Apparatus Availability, Ready Reserve apparatus may be used to replace Front- line apparatus placed out-of-service for mechanical repairs for a maximum of how long ?
8 hours
According to the Manual of Operation Volume 3, 7/1-72.00, Ready Reserve Engines, are designed to provide surge capacity during all of the following EXCEPT: high hazard days, emergency recall, and redeployment of staff personnel. Appropriate use of a Ready Reserve Engine includes cases where a company may put the apparatus in service while their first-line apparatus is at pump test, in and out repairs, etc.
-High hazard days
-Emergency recall and redeployment of staff personnel
-In and out repairs
-All of the above
According to Training Bulletin # 155, Wildland Urban Interface (WUI) Structure Defense, maintain what distance away from transmission lines?
35 feet
According to Book 6, AOTM, what is an engine overload condition which shortens engine life ?
Lugging
According to Training Bulletin # 135, The Hartford Consensus’ practical recommendations include the actions contained in the acronym THREAT: What does the “A” stand for ?
Assessment by medical providers
According to Book 6, AOTM, For each 1,000 feet of elevation, the power generated by internal combustion engines decreases about how much percent ?
3.5 %
According to Training Bulletin # 4, Gasoline Tank Truck-Trailer Incidents, what is the minimum size hose line you use for tire fires ?
1 1/2 inch
According to Training Bulletin # 69 Maxi-Force Air Bag System, Do not inflate the bag over ______ psi without a load.
30 psi
According to Departmental Bulletin 22-02, High Visibility Vest, The HVV is made of 100% polyester material with a ______ -point breakaway design to minimize the risk of becoming entangled in equipment and allowing for greater mobility in critical situations.
five-point
According to Book 99, Brush Operations Manual, The following steps shall be used to set up the water shuttle assembly with two Firefighters who will remove the following equipment, EXCEPT ?
-2 1/2” gated wye
-2 1/2” double male
-2 1/2” TO 1 1/2” gated wye
-2 1/2” to 1 1/2” reducer
According to Training Bulletin # 93, Thermo-Gel Fire Blocking Gel, Coat the object until white, the coating should be applied to what thickness ?
1/4 inch
According to Training Bulletin # 70, Metro Rail Blue Line, The most difficult manual method for lowering the pantograph is on the P-865’s and P-2020’s. Both types of LRV’s use the same method, by using a foot pump to lower the pantograph. The foot pump can be found where?
The second forward facing seat behind the train operator’s seat on the “A” section of the LRV.
According to Training Bulletin # 103, Foam Dispensing Equipment, what is the desired mixture for Class “B” flammable liquids/polar solvents ?
3 %
According to the Manual of Operation Vol 4/2-01.51, Hydrants, what is the designation used on Department maps to indicate a private fire hydrant ?
Square Box
According to Training Bulletin #149, Residential Sprinkler Systems, extended coverage heads can cover what size area ?
20 x 20 feet
According to Training Bulletin # 127, Inspection Cycles & Inspection Guides for Apparatus, PPE, and SCBA, what form number is the Heavy Apparatus Undercarriage Inspection Report ?
F-978B
According to Departmental Bulletin 13-04, regarding Vacant/abandoned marker hazard identification symbols, which symbol indicates holes in floor ?
H/F
According to the 99 Pierce Apparatus Logbook, what is the recommended foam concentration for overhaul ?
.1 %
According to the 2003 Seagrave Apparatus Logbook, The pump discharge pressure must be greater than ______ PSI for the PRO-S governor to take control of engine speed ?
15 psi
According to the 2003 Seagrave Apparatus Logbook, The pump is interlocked with the foam concentrate tank level switch. If the tank is empty, the pump will not run for more than how long ?
2 minutes
According to the 2005 Seagrave Apparatus Logbook, what is the rated oil pressure ?
45 psi
According to the 05 Pierce Apparatus Logbook, If the engine fails to start within _____ seconds, release the starter button and allow the starting motor to cool for approximately ______ seconds before trying again.
15;15
According to the 07 Pierce Apparatus Logbook, what is the normal operating range of the engine temperature?
189-208 degrees F
According to the 05 Pierce Apparatus Logbook, World Transmission: Checking Fluid Level. Perform a Hot Check at the first opportunity after normal operating temperature _____-_____ is reached.
160-200 degrees F
According to Book 57, LA Fire Code 2020, what is the required fire flow in Gallons Per Minute (GPM) for industrial and commercial areas ?
6,000-9,000 GPM
According to Book 57, LA Fire Code 2020, what is the spacing of fire hydrants in a high density residential and neighborhood commercial area ?
300-450 feet
According to Vol 4 8/8-25.37, Inventory, what is the maximum number of 16 cu. ft. “D” cylinders an engine may have on hand at any time including those carried on the apparatus and spare ?
3