PV System Mechanical Design Flashcards

Use this deck to learn about all of the mechanical design aspects of a PV system installation.

1
Q

You check the polarity of the PV output before applying ______ to ______.

A

PV power to an inverter, a charge controller, batteries, or a load

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The battery bank for a battery backup utility-interactive PV system is located in a harsh environment with temperature and humidity extremes. What are the most likely effects on the battery’s state of charge?

A

Undercharged in cold weather and overcharged in hot weather

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A 1/4” x 3 1/2” lag screw that has a 3” thread is used to attach an L- bracket to an asphalt-shingle roof. If the combined thickness of the L- bracket, shingles, and roof membrane is 3/4”, and if the screw penetrates directly into a roof truss made of Southern Yellow Pine into a properly sized pilot hole, then what is the withdrawal resistance?

A

773 Ohms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

In a PV system, which equipment is colored in green?

A

The grounding conductors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

If your magnetic compass is in San Francisco, CA and is showing that your array is aiming to the heading of 189 degrees, what is the azimuth of solar (true) south?

A

-24 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

In DC PV systems, what is the function of bare copper?

A

It’s usually not carrying substantial current

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Of the following site assessment tools, which are most often needed to determine optimal array placement?

  • sun path analyzer
  • pliers
  • Inclinometer
  • compass
  • voltmeter
A

Compass, inclinometer, and sun path analyzer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

A PV array for a utility-interactive system is to be ground-mounted on a hill 1,000 feet from the point of utility connection. It uses a 240 V inverter, and a single string of 1W modules operates between 300 and 550 volts DC. There is a small building halfway between the array location and the utility point of connection. To minimize wire size, increase performance, and ensure consistent operation, where should the inverter be installed?

A

At the utility point of connection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What does green mean in an AC system?

A

Ground

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Under what conditions does thin-film PV respond less than polycrystalline PV?

A

Heat and shading

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the required minimum working space width in front of a 48 V lead acid battery bank?

A

30” or the width of the battery bank, whichever is greater

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Areas of low wind, latitude greater than 30 degrees, and minimal daytime summer cloud cover are optimal conditions for what?

A

Two-axis tracking mount

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

A PV array for a utility-interactive system is to be ground-mounted on a hill 1,000 ft from the point of utility connection. The single string of 1W modules operates between 300 and 550 volts DC. The inverter is a 240 V inverter. There is a small building halfway between the array location and the utility point of connection. The utility point connection will do what for the inverter?

A

Minimize wire size, increase performance, and ensure consistent operation.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the cost advantage of thin-film?

A

Can be cheaper per watt to produce

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

PV systems located far south should do what to optimize performance?

A

Increase the tilt angle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Four PV modules, each with an area of 10 ft2, are to be mounted with a stand-off mount secured to a metal seam roof with L-brackets. If the modules can withstand a load of 75 lbs/ft2, and it is desired to support the full load with one lag screw in each bracket, and each screw has a withdrawal resistance of 300 lb/in2 including a safety factor of 4, the minimum screw thread length to penetrate would be…

17
Q

A proposed PV installation site has an unobstructed south-facing roof area of 60 m2. If thin-film modules with six watts-per-square-foot power output at STC are to be installed on 50% of the roof, then the maximum available PV array output power (based on the sum of module ratings) at STC will be…

A

1900 watts

18
Q

As it relates to PV system mechanical design, the closer you are to the north, what action will optimize performance?

A

Decrease your tilt angle

19
Q

A small conductor between the array and the inverter is a characteristic of a 500 V DC PV array and gives it an advantage over what kind of array?

A

A 48 V DC array of the same wattage

20
Q

What is distributed generation?

A

Smaller systems produce electricity close to consumption needs

21
Q

What is the most important consideration of mounting PV arrays on residential rooftops with regard to energy production?

22
Q

30 inches, or the width of the battery bank, is the required minimum for what?

A

Working space width in front of a 48 V lead acid battery bank

23
Q

Shading is the most important consideration for what?

A

For mounting PV arrays on residential rooftops with regard to energy production

24
Q

It is important to have what in coastal areas where the air contains salt spray?

A

Stainless-steel hardware

25
When many smaller systems produce electricity that meets consumption needs, what is it called?
Distributed generation
26
In DC PV systems, what is usually NOT carrying substantial generation?
Bare copper
27
Arrays are common components in what?
All PV systems
28
Stainless-steel hardware is most important in which areas?
Coastal areas where the air contains salt spray
29
A compass, inclinometer, and sun path analyzer are site assessment tools used for what?
Determining the optimal array placement
30
Before applying PV power to either an inverter, a charge controller, batteries, or a load, one should first do what?
Check the polarity of the PV output
31
Heat and shading have what effect on thin-film PV?
Decreased responsiveness, compared to polycrystalline PV
32
What kind of PV system promises to be cheaper per watt to produce?
Thin-film