Electricity Basics Flashcards
Use this deck to learn about all of the basics of electricity.
A 2500-W inverter is used to supply a 120-V AC load of 1500 watts. The ampacity of the wire at the inverter output must be at least how much?
26 A
What determines the voltage drop (not voltage drop percentage)?
Resistance and current
The duration, path, and path amount of current are all factors that depend on what?
The severity of electrical shock
What is a common use for linear current boosters?
Direct pumping applications and drop voltage
How does a battery charger work?
A battery charger sends an electric current through the battery in an efficient manner
Wire width determines what?
Ampacity
What are sealed batteries?
Valve-regulated lead-acid batteries
Four 6-volt, 240-Ah batteries are connected in 2 series groups, and there are 120-Ah batteries by another manufacturer available. Under what circumstance is it acceptable to incorporate all of these batteries into a 12-volt PV battery storage bank?
There is no acceptable connection of the batteries into a single battery bank
Can the same inverter used for a grid-tied system be used for off-grid with a charge controller?
No
A 26 ampacity of the wire at the inverter output with a 2500-W inverter is used to supply what?
A 120-V AC load of 1500 watts
If the maximum AC output of an inverter with 120-V AC output is 1500 W, what should be the rating of the circuit breaker at the point-of-utility connection?
20A
What is measured in watts per square meter?
Irradiance
What is the first step in system checkout?
Visually checking the entire system
All else being equal, what happens to temperatue when PV system voltage increases?
Since voltage and temperature have an inverse relationship, temperatue will decrease as PV system voltage increases.
What can a bimodal do?
It can work as grid-tied or stand-alone
What does low cell temperature do?
Increases voltage
What does irradiance proportionally affect?
Amperage
If the open circuit voltage (Voc) of a crystalline silicon PV array is 315V at 25 degree Celcius (STC), then according to the NEC (National Electric Code) chart, if the array is operated at -20 degrees Fahrenheit, maximum system voltage must be corrected to?
369 V
What is between the inverter and the array?
DC disconnect and/or sometimes a charge controller
A crystalline silicon PV array that has bipolar outputs of + 252V and - 252V with a common grounded conductor under Standard Test Condition is selected for a large single-family residence. The lowest expected temperature at the installation site is -25 degrees C. For this system, the maximum system voltage is closest to what?
605V
Valve-regulated lead-acid is a type of battery that is between what?
Sealed batteries
What can coincide with a loss of power in a 2 phase system?
Loss of power in a 3 phase system
What is an advantage of larger wire size?
Lower wire temperature, which decreases overall risk of electrical hazards.
What type of measurement do amperes express?
Rate of electric charge in circuit (current)