Pumping Flashcards
Pump Recirculating Line valve
1/2” line
The transmission defaults to ___ when placed
in pump.
4th gear
Operate priming pump until main suction gauge shows a vacuum of approximately
____ and main pressure gauge shows a positive pressure.
20” of Hg
NOTE: If you are not
able to achieve prime within ___, stop and investigate.
45 seconds
Pro-S Governor
The pump discharge pressure is monitored and can vary but will be limited to an increase of ___
30 PSI.
The minimum pump discharge pressure must be greater than ___ for the PRO-S governor to take control of engine speed.
15 PSI
In Pressure Mode, press either button momentarily to change the pressure setting by 1 PSI. Press and hold the button for more than 2 seconds and the pressure setting will change by___ and then by ____ until the button is released.
5 PSI twice / 10 PSI
In RPM Mode, press either button momentarily to change the RPM setting by 10 RPM. Press and hold the button for more than 2 seconds and the RPM setting will change by___ and then by ___ until the button is released.
50 RPM twice / 100 RPM
If the discharge pressure drops below ___ but stays above ___ the PRO-S will go into a prime cycle. It will set the engine to ____.
45 PSI / 15 PSI / 1100 RPM.
If the pressure does not rise above 45 PSI in ___ the PRO-S will set the engine at idle RPM.
7 seconds
The pump discharge pressure can vary but, as a safety feature, the PRO-S limits the increase in pressure to ___.
30 PSI
In order to pump pressures over___, the Pressure Governor must be operated in the ____
300 psi / RPM Mode.