Foam Pro Flashcards
External factors such as ___ will not affect performance or accuracy.
hose length, elevation, nozzles, kinks or incoming pressure
The system is capable of proportioning foam between ___
0.1% to 3.0%.
0.2% Foam
1300 GPM
0.5% Foam
520 GPM
1.0% Foam
260 GPM
3.0% Foam
85 GPM
The maximum operating pressure of the Foam Pro Model 2001 Foam System is____.
400 psi
If the tank is empty, the pump will not run for more than ___.
2 minutes
Motor stall protection is provided. In the event that the pump motor will not run or stalls for ____, the display will show “ERR.EL” to indicate that the pump is producing no feedback to the control signal.
10 seconds
When the fire pump is running, the foam pump cannot pump air efficiently against ____ backpressure.
100 to 150 psi
In order to pump pressures over___, the Pressure Governor must be operated in the___
300 psi / RPM Mode.