Pump Card Flashcards
What are the hose and nozzle for high rise operations?
200’ 2.5” hose with 1 1/8” SB tip.
What is the pump pressure for floors 1-5 for high rise ops?
160psi
How much pressure do you add for 5 floors on high rise ops?
35 or 7psi per floor. Example floors 6-10 195psi.
FL per 100’ for 1.75” 100gpm?
5
FL per 100’ for 1.75” 125gpm?
10
FL per 100’ 1.75” 150gpm?
15
FL per 100’ 1.75” 175gpm
20
FL per 100’ 1.75” 200gpm?
25
FL per 100’ 2.5” 250gpm?
10
FL per 100’ 2.5” 350gpm?
25
FL per 100’ 2.5” 500gpm?
50
FL per 100’ 3” 250gpm?
5
FL per 100’ 3” 350gpm?
15
FL per 100’ 3” 500gpm?
30
FL per 100’ 4” 500gpm?
5
FL per 100’ 4” 1000gpm?
20
FL per 100’ 4” 1500gpm?
45
FL per 100’ 4” 2000gpm?
80
FL per 100’ 5” 1000gpm?
5
FL per 100’ 5” 1500gpm?
10
FL per 100’ 5” 2000gpm?
20
TFT Metro 1.5” NOZZLE GPM?
175gpm
TFT Metro 1.5” NOZZLE psi?
75psi
TFT Metro 2.5” NOZZLE GPM?
250gpm
TFT Metro 2.5” NOZZLE psi?
50psi
Pump solid tip handline at?
50psi
Pump solid tip master stream at?
80psi
Friction loss of Siamese/wye?
10psi