What are the hose and nozzle for high rise operations?
200’ 2.5” hose with 1 1/8” SB tip.
What is the pump pressure for floors 1-5 for high rise ops?
160psi
How much pressure do you add for 5 floors on high rise ops?
35 or 7psi per floor. Example floors 6-10 195psi.
FL per 100’ for 1.75” 100gpm?
5
FL per 100’ for 1.75” 125gpm?
10
FL per 100’ 1.75” 150gpm?
15
FL per 100’ 1.75” 175gpm
20
FL per 100’ 1.75” 200gpm?
25
FL per 100’ 2.5” 250gpm?
10
FL per 100’ 2.5” 350gpm?
25
FL per 100’ 2.5” 500gpm?
50
FL per 100’ 3” 250gpm?
5
FL per 100’ 3” 350gpm?
15
FL per 100’ 3” 500gpm?
30
FL per 100’ 4” 500gpm?
5
FL per 100’ 4” 1000gpm?
20
FL per 100’ 4” 1500gpm?
45
FL per 100’ 4” 2000gpm?
80
FL per 100’ 5” 1000gpm?
5
FL per 100’ 5” 1500gpm?
10
FL per 100’ 5” 2000gpm?
20
TFT Metro 1.5” NOZZLE GPM?
175gpm
TFT Metro 1.5” NOZZLE psi?
75psi
TFT Metro 2.5” NOZZLE GPM?
250gpm
TFT Metro 2.5” NOZZLE psi?
50psi
Pump solid tip handline at?
50psi
Pump solid tip master stream at?
80psi
Friction loss of Siamese/wye?
10psi
Gpm of Siamese/wye?
350+ gpm
TFT Inline Eductor gpm?
125gpm
Pump TFT Inline Eductor at?
200 + friction loss
TFT blitzfire gpm?
100 - 500gpm
Pump TFT blitzfire at?
55 or 100 + friction loss
Deckgun gpm?
1500gpm
Pump deckgun at?
120psi
Skyboom gpm?
1000gpm
Pump Skyboom at?
150psi
Aerial ladder gpm?
1000gpm
Pump to aerial ladder?
180 + friction loss
95’ platform gpm?
1000-1500gpm
Pump to 95’ platform at?
180 + friction loss
Pump to Hydra assist at?
20 + friction loss
Series pumping gpm?
1000gpm
What do you pump for series pumping?
1/2 total psi + friction loss
Relay pumping gpm?
1000gpm
How do you pump for relay pumping?
20 + friction loss
Puncture nozzle gpm?
75gpm
Standpipe/sprinkler gpm?
500gpm
What do you pump standpipe/sprinkler at?
125 + EP
Miller sprinkler gpm?
200gpm
What do you pump the Miller sprinkler at?
125 + EP
1.5” TFT foam nozzle gpm?
125gpm
What do you pump the 1.5” TFT foam nozzle at?
75psi
0.75” tip size = ___ gpm @ 50psi.
100gpm
7/8” tip size = ___ gpm @ 50psi.
150gpm
15/16” tip size = ___ gpm @ 50psi.
185gpm
1” tip size = ___ gpm @ 50psi.
200gpm
1 1/8” tip size = ___ gpm @ 50psi.
250gpm
1 1/4” tip size = ___ gpm @ 50psi.
300gpm
1 1/4” master stream ___ gpm @ 80psi
400gpm
1 3/8” master stream ___ gpm @ 80psi
500gpm
1 1/2” master stream ___ gpm @ 80psi
600gpm
1 5/8” master stream ___ gpm @ 80psi
700gpm
1 3/4” master stream ___ gpm @ 80psi
800gpm
2” master stream ___ gpm @ 80psi
1000gpm
2 1/4” master stream ___ gpm @ 80psi
1350gpm
2 1/2” master stream ___ gpm @ 80psi
1650gpm
Which side of the hydra assist pumps to the fire?
Side B.
Which side of the hydra assist flows to the pump?
Side C.
Which side of the hydra assist pumps from the discharge?
Side D.
Operator of the hydra assist will open ___ and then ___.
The intake valve and then open the largest discharge.