Process Air Compressor Flashcards
1
Q
PAC Secondary Reformer Top Bed Trip
A
2200 degrees Fahrenheit
TT-1098
2
Q
PAC Secondary Reformer Middle Bed Trip
A
2000 degrees Fahrenheit
TT-1099
3
Q
PAC Secondary Reformer Outlet Trip
A
2000 degrees Fahrenheit
TT-1100
4
Q
PAC Discharge or Low Process Air Trip
A
400 MSCF/H
FT-2203C, D, E
5
Q
PAC low lubee oil trip
A
1 psig
PSLL-63
6
Q
PAC CCC over Speed trip
A
7550 RPM
K-2025D
7
Q
PAC Protech Overspeed
A
7531 RPM
OS-2025T
8
Q
PAC low speed
A
5700 RPM
Interstate vent opens
9
Q
PAC Bently Hi Thrust Shutdown
A
25mils or -25mils
C2025-BNSD