Q

If additional exit facilities are provided, the occupancy load of a facility can be increased by what % with approval of the chief

A

10%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Converting organic peroxides from gallons to pounds. 1 gal =

A

10 lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Hydrant spacing residentials.

A

600ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
  1. Hydrant shut off within
A

10-25 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When are onsite hydrants required for facilities and buildings. When any portion of the building in excess of _____ from water supply on public street

A

150Ft

?? could not find in book

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Once building or a piece of equipment have been red tagged, who authorizes removal of red tag

A

. Fire Dept. Representative only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
  1. Access roads for high piled stock
A

150 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q
  1. If more than one hydrant is to be flowed in order to meet the required fire flow for TWO public hydrants flowing simultaneously
A

1251-3500 Gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
  1. Who shall approve location of key box
A

Station captain

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q
  1. All sprinkler plans include fire flow test dates obtained within
A

6 Months

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

For commercial sprinkler systems in multi floor building, floor control valves shall be required if exceeds

A

3 floors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

For onsite hydrant spacing only sprinklered buildings qualify for max spacing.

A

600 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

An infraction is punishable by fire not to exceed $50.

A

1st violation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Hi-Rise personnel from management implement safety plan called

A

Fire Safety Director

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

R-3. Large family day care.

A

7-12 kids

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Factories using entirely non-combustible and non-explosive materials are an ___ occupancy

A

F-2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Fire work stands max square footage.

A

400 ft squared

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

High Rise stock > ___’ requires permit if > ___ square ft.

A

12’

500

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Bonfires shall not be __ft. from structures or combustible materials/
spectators min din distance ___ ft.

A

50

100

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

License requirement for maintenance of sprinklers.

A

No license needed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Hydrants have __ ft clearance

A

3

22
Q

Fuel dispensing station with ___‘not less ___’

A

100

20

23
Q

Fire prevention permits are non transferable

A

T

24
Q

Group H occupancy

A

Div 3

25
Q

E-2 occupancy is edu for

A

50

26
Q

Fire apparatus roads. ___ ft. wide clear to sky

A

20

27
Q

Pools in zone 4, 5000 gallons need __” drain

A

4

28
Q

Class II standpipes 100 ft. hose nozzle within __ ft. portions of building

A

30

29
Q

Hood system have fusible link replaced ________

A

annually

30
Q

Spray finish operations shall have approved automatic extinguishing system

A

T

31
Q

UFC combined total of flammable liquids not exceed ___ gallons

A

120

32
Q

High piled stock will have doors ____ ft. of exterior wall facing road.

A

100

33
Q

Storage tank out of service? Have Fill line, Gauge opening, Vapor return, Pump connection

A

T

34
Q

Damage to private hydrant. _____

A

form 410

35
Q

Address #’s on roof of high rise visible from ___

A

500’

36
Q

An approved apparatus access road shall be provided within ___“of all first floor exterior walls

A

150’

37
Q

Security gates will have approved means of emergency operations

A

T

38
Q

Emergency escape openings shall be operational from inside without ___ ____ ____

A

keys tools or effort

39
Q

Extension cords not through walls or permanent or under floors

A

T

40
Q

Exit sign. __” letters

A

6

41
Q

Private hydrant within a 25’ of _ hr wall

A

2

42
Q

Hydrant back from curb. __-___

A

12-24

43
Q

Exit Doors swing outward. ____ people

A

25

44
Q

Standpipes should be inspected

A

semi-annually

45
Q

High piled stock >

A

12 ft.

46
Q

Hazmat handler has at any one time:

A

55 gallons, 300 lbs, 200 cubic feet compressed gas

47
Q

Hydrant spacing commercial.

A

300 ft

48
Q

Minimum fire flow for single family dwelling on lot 1 acre or more in Fire zone 3.

A

750 Gpm

49
Q

V7 Ch1 S15 Unobstructed access clear to sky for fire fighting purpose required when equipment must use access routes other than improved dedicated public roads to get within 150ft away from 1 story of any structure?

A

t

50
Q

Fire code for places of assembly. If denied entry into public assembly while investigating over crowding. 1st step, leave &

A

contact BC/law