practice test 2nd attempt Flashcards
Which of the following are typically considered part of the FF&E contract? (Choose the four that apply.)
A. a commissioned sculpture bolted to a wall
B. vending machines built into an opening
C. auditorium seating
D. wall-to-wall carpeting
E. applied acoustical panels
F. vertical blinds
A. a commissioned sculpture bolted to a wall
B. vending machines built into an opening
C. auditorium seating
F. vertical blinds
Which of the following is true of title acts versus practice acts regulating the practice of interior design?
A. practice acts require meeting educational requirements and passing the NCIDQ exam
B. states with title acts requiring continuing education to keep their license current
C. the allowable titles under title laws are uniform for each state
D. practice acts do not allow the use of the title “interior decorator”
A. practice acts require meeting educational requirements and passing the NCIDQ exam
A chef is considering the purchase of an abandoned church, with the intention of turning it into a restaurant. The property’s zoning designation allows this type of use. The chef has obtained a preliminary site plan and permission to access the site from the current owner and hires and interior designer to assist with a feasibility study to examine the possibility of converting the old building to the new use. Which of the following should the interior designer do first?
A. Check local zoning ordinances and analyze the site to determine if there is enough space available for the parking required.
B. Assist the restaurateur in developing a program and check the space requirements against the area and layout of the existing structure.
C. Research the history of the church.
D. Complete a code review of the existing building and develop a preliminary plan for renovation.
B. Assist the restaurateur in developing a program and check the space requirements against the area and layout of the existing structure.
A transaction privilege tax license allows an interior design firm to
A. conduct business
B. buy and sell furniture
C. bill clients for the cost of employees
D. charge clients for installation services
B. buy and sell furniture
An interior designer has determined the required gross occupant area required for a client planning to lease space in an office building. Using the Building Owner and Managers Association (BOMA) standard ANSI/BOMA Z65.1, Office Buildings: Standard Methods of Measurement, which of the following would be used to determine the amount of lease space the client will be paying for?
A. building efficiency ratio
B. building load factor
C. R/U ratio
D. rentable area
B. building load factor
Which of the following provides the MOST accurate basis for estimating project costs?
A. square footage
B. functional unit
C. parameter
D. quantity takeoff
D. quantity takeoff
Which of the following constitutes due diligence in the field of interior design?
A. thoroughly understanding and documenting the space in which a client’s project will be located and its surround context
B. reviewing the legal and regulatory components of a new project before design begins
C. using qualified structural, engineering, and fire protection consultants to investigate and existing space before design begins
D. reviewing and verifying site conditions that the client has reported to the interior designer
A. thoroughly understanding and documenting the space in which a client’s project will be located and its surround context
An interior designer beginning a multifamily housing project would want to consult the
A. ADA Standards for Accessible Design
B. Fair Housing Act
C. International Building Code
D. Uniform Federal Accessibility Standards
B. Fair Housing Act
An interior designer is assisting a law firm in selecting one of two buildings in which to lease space. After programming, the designer determines that the client will need 6500 ft^2 (604 m^2) of net assignable area. In building A, the designer estimates that the efficiency factor will be approximately 80%. In building B, because of the irregular shape of the floor plate, the designer estimates that the efficiency factor will probably be closer to 75%. The leasing agent in building A tells the designer that the building load factor is 1.23, while the leasing agent in building B tells the designer that the building load factor is 1.20. Of the two buildings, to the nearest 100 ft^2 (100 m^2), the smaller rentable area is
10000
ft^2 (
900
m^2). (Fill in the blank.)
Answer 1:
Correct!10000
Answer 2:
Correct!900
Answer 1:
Correct!10000
Answer 2:
Correct!900
Who is responsible for determining the location and general condition of existing light fixtures as part of a due diligence investigation?
A. electrical engineer
B. electrical subcontractor
C. general contractor
D. interior designer
D. interior designer
Which type of accounting would MOST likely be chosen by an interior designer working alone as a sole proprietorship?
A. accrual
B. cash
C. double-entry
D. leger-based
B. cash
An interior designer wants to specify acoustic insulation. Which type of specification should be used?
A. performance
B. prescriptive
C. proprietary
D. reference
D. reference
To avoid liens against a project, the interior designer should suggest the owner require the contractor to submit a
A. bid bond
B. bid security
C. performance bond
D. labor and material payment bond
D. labor and material payment bond
Which of the following is the interior designer’s BEST source for determining a piece of furniture’s net price?
A. showroom manager
B. manufacturer’s price list
C. furniture dealership
D. representative’s line chart
C. furniture dealership
One of the primary advantages of a full wall schedule is that it
A. takes less time to develop than a CPM chart
B. is more detailed than a Gantt chart
C. is large enough for several people to view at once
D. involves the entire project team in the scheduling
D. involves the entire project team in the scheduling
An interior designer’s drawings indicate an area of hardwood flooring with an indeterminate boundary because the client is still deciding on the flooring’s actual area. To ensure that bid prices for the flooring are compared fairly, which of the following should the interior designer request be included on the bid form?
A. individual quotes
B. unit prices
C. fixed costs
D. contingencies
B. unit prices
Tracking, or monitoring, a project during design and construction, whether by hand-made chart or computer program, involves
A. using time sheets to measure productivity and minimum billing rates
B. comparing estimated fees and time against actual expenditures and percent complete
C. comparing client expectations at regular intervals during construction against original goals
D. verifying actual construction costs against the estimated budget as the project is completed
B. comparing estimated fees and time against actual expenditures and percent complete
In addition to the ability to pass the hose stream test and size limitations, what other factors must be considered when selecting fire-resistive-rated glazing for a corridor in an interior project?
A. impact rating and requirements for a heat barrier
B. certification of the manufacturer and impact rating
C. the direction of the expected fire attack
D. requirements for a heat barrier and certification of the manufacturer
A. impact rating and requirements for a heat barrier
To verify a manufacturer’s claim that its product has met the requirements of an ASTM standard, the interior designer should
A. contact the relevant trade association for the project
B. contact ASTM and get a copy of the standard
C. investigate the standard on internet sites
D. request detailed information from the manufacturer
D. request detailed information from the manufacturer
When coordinating with a security consultant, the interior designer’s drawings should show
A. a schedule of all security devices
B. the emergency backup power supply
C. the positioning of required lighting
D. the wiring of the security devices
C. the positioning of required lighting
In the furniture procurement process, the interior designer gives the exact requirements of what the client has selected with the
A. sales agreement
B. acknowledgement
C. purchase order
D. freight billing
C. purchase order
Which of the following are typically part of the furniture, fixtures, and equipment (FF&E) budget? (Choose the four that apply.)
A. appliances
B. lamps
C. chandeliers
D. wood cabinets
E. rugs and mats
F. window coverings
A. appliances
B. lamps
E. rugs and mats
F. window coverings
What type of sprinkler head should be used for a decorative, open-grid, wood-slat ceiling suspended from the structural floor above?
A. upright
B. pendant
C. sidewall
D. recessed
A. upright
During the design development phase of planning a large classroom, which of the following methods could be used to reduce potential noise problems in a room of a given area whose exact shape has not yet been determined? (Choose the four that apply.)
A. Design the room to have the largest ceiling surface area possible.
B. Minimize the length of the wall separating the classroom from the nosiest adjacent room.
C. Plan to install sound-absorbent material on the walls of the classroom.
D. Study ways to increase the transmission loss of the room’s partitions.
E Specify a white noise system for the room.
F. Locate the doors to the classroom away from doors of nearby rooms.
B. Minimize the length of the wall separating the classroom from the nosiest adjacent room.
C. Plan to install sound-absorbent material on the walls of the classroom.
D. Study ways to increase the transmission loss of the room’s partitions.
F. Locate the doors to the classroom away from doors of nearby rooms.
What type of system would be BEST for an open office plan so the heating and cooling for each workstation could be individually controlled?
A. all-air system
B. all-water system
C. radiant panel system
D. air-water system
A. all-air system
What reference standards should be used to determine the most complete and detailed requirements for sprinkler spacing and positioning?
A. IBC
B. IPC
C. IMC
D. NFPA
D. NFPA
Which of the following are important criteria for evaluating the selection of building materials with the goal of conserving resources? (Choose the four that apply.)
A. recycled content
B. maintainability
C. potential for reuse
D. embodied energy
E low toxicity
F. amount of renewable raw materials
A. recycled content
C. potential for reuse
D. embodied energy
F. amount of renewable raw materials
The location of a new toilet room in an existing building would be MOST limited by the
A. location of cold water pipes
B. position of existing vent stacks
C. location of an overhead structural beam
D. distance from the nearest soil stack
D. distance from the nearest soil stack
On projects that involve both construction and furniture, fixtures, and equipment (FF&E), why are FF&E typically separate budget items from construction?
A. they are specified, purchased, and installed differently than construction
B. they are purchased wholesale by the interior designer with a markup applied
C. most clients maintain separate monetary accounts for FF&E purchases
D. they contain things like artwork, rugs, and window coverings that the contractor can’t estimate
A. they are specified, purchased, and installed differently than construction
While there are minor variations in accessibility standards, which reference standard are they all based on?
A. 2010 ADA Standards for Accessible Design
B. 28 CFR 36
C. ADA/ABA Guidelines
D. ICC A117.1
D. ICC A117.1
Commercial-grade cabinets are MOST often constructed of panel products with a thickness of
A. ½ in (13 mm)
B. 5/8 in (16 mm)
C. ¾ in (19 mm)
D. 7/8 in (22 mm)
C. ¾ in (19 mm)
A Gantt chart is another name for a
A. bar chart
B. full wall chart
D. critical path chart
D. PERT chart
A. bar chart
Air is most effectively distributed along an exterior window wall by a
A. round diffuser
B. square grille
C. series of square diffusers
D. slot air diffuser
D. slot air diffuser
Which of the following are MOST likely to be part of the project manager’s responsibilities? (Choose the four that apply.)
A. keeping notes on daily decisions and meetings
B. organizing the layout of construction drawings
C. generating strategic, long-term goals for the firm
D. planning and assigning weekly job tasks for the project staff
E. monitoring fee expenditures throughout all phases of the project
F. staying current with the client’s opinion of the progress of the project
A. keeping notes on daily decisions and meetings
D. planning and assigning weekly job tasks for the project staff
E. monitoring fee expenditures throughout all phases of the project
F. staying current with the client’s opinion of the progress of the project
What document is used to approve the release of funds for furnishing a project?
A. application for payment
B. certificate for payment
C. purchase order
D. bill of lading
C. purchase order
When designing and specifying acoustic panes for sound control, what are the most important considerations? (Choose the four that apply.)
A. permeable fabric
B. hydrophobic fabric
C. loose core material
D. tackable core material
E. fabric color
F. unbacked fabric
A. permeable fabric
B. hydrophobic fabric
C. loose core material
F. unbacked fabric
When the interior designer does not want furniture to be delivered to the designer’s office, the designer should complete a
A. customized purchase order
B. drop ship order
C. letter of intent
D. tag for label
B. drop ship order
During the construction of a hotel lobby, the client decides to replace the porcelain tile floor specified for the floor with a poured terrazzo flooring material. The interior designer requests a proposal from the contractor for the change. The contract states that the contractor may add 20% for overhead and profit and an additional 5% for coordination on change orders. The contractor’s base price for labor and materials for the change is $22,225. What is the approximate total value for the change order?
A. $26,000
B. $27,000
C. $28,000
D. $29,000
C. $28,000
A client has requested that special security protection be provided at a reasonable cost for critical paper files containing corporate trade secrets. In designing the file room, the interior designer should suggest
A. card readers at the doors leading to the file room
B. photoelectric beams within the room
C. magnetic contacts on all doors leading to the file room
D. electronic shielding of the file room
A. card readers at the doors leading to the file room
In order to easily understand what types of visible and audio alarms are required for a project and where they are required, what reference would the interior designer find most useful and easy to use?
A. International Building Code
B. International Fire Code
C. National Electrical Code
D. NFPA National Fire Alarm and Signaling Code
A. International Building Code