IDPX Practice Exam 1 Flashcards
Who is responsible for showing the telephone and data conduit runs on the drawings for a commercial design project?
A. architect
B. electrical engineer
C. interior designer
D. telephone installer
B. electrical engineer
Which are the MOST important factors in determining the space required for a nurses’ station in a hospital?
A. number of patient contacts and files
B. work surface and storage requirements
C. number of moveable carts and space requirements for writing reports
D. electrical and communication equipment requirements
B. work surface and storage requirements
The designer for the interior designer furnishings of a large public hospital project financed with bond money has assisted the city government in preparing the bidding documents. When the bids from five qualified contractors are opened, they are all over budged, ranging from 4% to 10% over the approved costs. What should the designer do?
A. Recommend that the city accept the lowest bid and obtain the extra 4% from other sources.
B. Begin to study ways to reduce the projects scope so it meets the budget.
C. Suggest that the project be rebid because the lowest bid is so close to the budget.
D. Wait for the city to tell the designer how it wants to proceed.
B. Begin to study ways to reduce the projects scope so it meets the budget.
In addition to the ability to pass the hose stream test and size limitations, what other factors must be considered when selecting fire-resistive-rated glazing for a corridor in an interior project?
A. impact rating and requirements for a heat barrier
B. certification of the manufacturer and impact rating
C. the direction of the expected fire attack
D. requirements for a heat barrier and certification of the manufacturer
A. impact rating and requirements for a heat barrier
After creating the reception desk action detail, the interior designer must consult with the
A. electrical engineer
B. building owner
C. furniture dealer
D. mechanical engineer
A. electrical engineer
An interior designer’s drawings indicate an area of hardwood flooring with an indeterminate boundary because the client is still deciding on the flooring’s actual area. To ensure that bid prices for the flooring are compared fairly, which of the following should the interior designer request be included on the bid form?
A. individual quotes
B. unit prices
C. fixed costs
D. contingencies
B. unit prices
A change in use in an existing building requires the interior designer to first research
A. the allowable square footage established by the building code for the new use
B. the number, location, and separation of the exits to the outside
C. maximum travel distance of the old use compared with the new use
D. the existing construction type
A. the allowable square footage established by the building code for the new use
Which of the following energy conservation standards is the interior designer most likely to use when designing a commercial project?
A. IgCC
B. IBC
C. IECC
D. IRC
C. IECC
A client has asked an interior designer to work on a new project that will involve changing the use of an existing building from a four-plex residence to an artists’ cooperative workplace. What agency must the designer first consult to determine if this would be possible?
A. building department
B. city council
C. planning commission
D. zoning department
D. zoning department
When is the application for a commercial building permit submitted?
A. when the construction drawings are 95% complete
B. when the interior designer has completed the construction documents
C. after the contractor has approved the final construction documents
D. when the owner has received the final copy of the drawings and specifications
B. when the interior designer has completed the construction documents
Which of the following is used to accommodate costs that are not yet confirmed at the time of a bid?
A. allowance
B. add-alternate
C. material bond
D. unit price
A. allowance
ASTM is a(n)
A. model code group
B. industry standard-writing organization
C. testing laboratory
D. federal code-writing agency
B. industry standard-writing organization
An interior designer is assisting a law firm in selecting one of two buildings in which to lease space. After programming, the designer determines that the client will need 6500 ft^2 (604 m^2) of net assignable area. In building A, the designer estimates that the efficiency factor will be approximately 80%. In building B, because of the irregular shape of the floor plate, the designer estimates that the efficiency factor will probably be closer to 75%. The leasing agent in building A tells the designer that the building load factor is 1.23, while the leasing agent in building B tells the designer that the building load factor is 1.20. Of the two buildings, to the nearest 100 ft^2 (100 m^2), the smaller rentable area is
7000
ft^2 (
6000
m^2). (Fill in the blank.)
Answer 1:
Correct Answer
10000
Answer 2:
Correct Answer
90
Answer 1:
Correct Answer
10000
Answer 2:
Correct Answer
90
Which of the following are advantages of negotiated contracts? (Choose the four that apply.)
A. The client can select the contractor based on criteria other than price.
B. The contractor will provide the highest-quality project.
C. The contract price will be lower than it would be under other contract types.
D. The schedule is generally shorter than it would be under other contract types.
E. The interior designer is involved in the process.
F. The client can select the subcontractors.
A. The client can select the contractor based on criteria other than price.
D. The schedule is generally shorter than it would be under other contract types.
E. The interior designer is involved in the process.
F. The client can select the subcontractors.
Which of the following organizations or standards establishes volatile organic compound (VOC) limits on indoor air quality for furniture systems?
A. BIFMA
B. EPA
C. IBC
D. IECC
A. BIFMA
An interior designer has been retained by the developer of a suburban retail complex to design the interior of a mid-size department store. The interior designer is working with the architect of the complex along with the architect’s consulting engineers. Which project participants are likely to have the most influence on the designer’s creative work? (Choose the three that apply.)
A. leasing agent
B. developer
C. department store owner
D. public
E. store employees
F. architect
B. developer
C. department store owner
D. public
What testing standard should be specified for the durability of office chair construction?
A. ANSI/BIFMA X5.1
B. ASTM D4157
C. CAL TB133
D. NFPA 701
A. ANSI/BIFMA X5.1
An interior design could determine which clients have not paid by looking at the
A. aged accounts receivable
B. balance sheet
C. cash flow statement
D. income statement
A. aged accounts receivable
In designing a new space, the interior designer can influence life safety the MOST by coordinating with consultants concerning
A. compartmentation
B. fire detection
C. smoke control
D. sprinklers
D. sprinklers
Where does a common path of egress travel end?
A. in an area of refuge
B. at the exterior exit from the building
C. at the point where an individual has a choice about which direction to go to reach an exit
D. at a public way
C. at the point where an individual has a choice about which direction to go to reach an exit
An interior designer recommends that a client purchase appliance directly rather than through a general contractor. What would be the primary reason for this recommendation?
A. The client could avoid the contractor’s markup.
B. The client could not be overcharged for delivery and installation.
C. The interior designer could provide the client a broader selection by acting as the client’s agent.
D. The client could get a better discount than the contractor.
A. The client could avoid the contractor’s markup.
The interior designer is responsible for which of the following aspects of consultant coordination? (Choose the four that apply.)
A. giving the electrical engineer information about the client’s equipment
B. providing the mechanical engineer with the occupant load for each space
C. informing the mechanical engineer about current sprinkler system codes
D. making sure that the final drawings and specifications are coordinated
E. telling the electrical engineer where to places the electrical closets
F. giving the electrical engineer the designer’s preferred choices for luminaires
A. giving the electrical engineer information about the client’s equipment
B. providing the mechanical engineer with the occupant load for each space
D. making sure that the final drawings and specifications are coordinated
F. giving the electrical engineer the designer’s preferred choices for luminaires
Which of the following facts about the surrounding neighborhood are relevant to whether a building can achieve the LEED for Commercial Interiors (LEED-CI) certification? (Choose the four that apply.)
A. All surrounding streets are collector or arterial.
B. The building is in a high-density, walkable community.
C. The number of guaranteed tenant parking spaces is the minimum allowed by the zoning requirements.
D. The site has sufficient access to sunlight from the south.
E. The site has sufficient bicycle facilities.
F. Public transportation is located within ¼ mi (0.4 km) of the project site.
B. The building is in a high-density, walkable community.
C. The number of guaranteed tenant parking spaces is the minimum allowed by the zoning requirements.
E. The site has sufficient bicycle facilities.
F. Public transportation is located within ¼ mi (0.4 km) of the project site.
When working under the requirements of the International Energy Conservation Code (IECC), the interior designer will MOST likely use which method to assist in the lighting design of a commercial project?
A. building area method
B. energy cost budget method
C. luminaire efficacy method
D. space-by-space method
D. space-by-space method