PRA Flashcards

1
Q

Risk Function

A

A designator for a train of equipment used to describing RICTCal or RAsCal maintenance states, such as “EWA” for ECW Train A or “IA11/12” for Instrument Air compressor 11 or 21.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Maintenance State

A

A combination of one or more Risk Functions, such as “EWA IA11/12 CCA” or “CW11/12”, used to describe the current plant configuration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

ICDP

ITP

A

Incremental Core Damage Probability

(Work Week Core Damage Risk)

Incremental Trip Probability

(Work Week Trip Risk)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Carryover Risk

A

Incremental risk (ICDP or ITP) which accrues due to maintenance in a given work week which began in a previous week.

Automatically handled in RAsCal and is displayed on the Entry tab. NOT shown in RICTCal because it is not possible to close a sequence with inoperable equipment.